Photon-Upconversion Barcoding with Multiple Barcode Channels: Application for Droplet Microfluidics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F19%3A00509591" target="_blank" >RIV/68081715:_____/19:00509591 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/11104/0300289" target="_blank" >http://hdl.handle.net/11104/0300289</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.analchem.9b0311" target="_blank" >10.1021/acs.analchem.9b0311</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Photon-Upconversion Barcoding with Multiple Barcode Channels: Application for Droplet Microfluidics
Popis výsledku v původním jazyce
Barcoding facilitates high-throughput analytical methods in complex matrixes with a reduced volume of sample, reagents, time, and cost. Because of orthogonality to fluorescence, photon-upconversion barcodes attracted considerable attention in recent years. We constructed an epiluminescence detector, which, for the first time, demonstrated the reading of photon-upconversion spectra from microdroplets in a microfluidic chip with frequency up to 10 Hz. Non-negative least-squares deconvolution enabled the reading of an unprecedented number of photon-upconversion barcode channels (six) from emission spectra (excitation 980 nm, emission 430-875 nm). The standard deviation of barcode reading from microdroplets was ∼1%. Described barcoding can be, for example, used for multiparameter titrations, multiplexed biological and chemical assays, optimizations on a microfluidic platform, and preparation of barcoded concentration gradients and libraries.
Název v anglickém jazyce
Photon-Upconversion Barcoding with Multiple Barcode Channels: Application for Droplet Microfluidics
Popis výsledku anglicky
Barcoding facilitates high-throughput analytical methods in complex matrixes with a reduced volume of sample, reagents, time, and cost. Because of orthogonality to fluorescence, photon-upconversion barcodes attracted considerable attention in recent years. We constructed an epiluminescence detector, which, for the first time, demonstrated the reading of photon-upconversion spectra from microdroplets in a microfluidic chip with frequency up to 10 Hz. Non-negative least-squares deconvolution enabled the reading of an unprecedented number of photon-upconversion barcode channels (six) from emission spectra (excitation 980 nm, emission 430-875 nm). The standard deviation of barcode reading from microdroplets was ∼1%. Described barcoding can be, for example, used for multiparameter titrations, multiplexed biological and chemical assays, optimizations on a microfluidic platform, and preparation of barcoded concentration gradients and libraries.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ18-03367Y" target="_blank" >GJ18-03367Y: Kódování s využitím fotonové upkonverze pro bioanalýzu v kapkové mikrofluidice</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Chemistry
ISSN
0003-2700
e-ISSN
—
Svazek periodika
91
Číslo periodika v rámci svazku
20
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
12630-12635
Kód UT WoS článku
000491219900007
EID výsledku v databázi Scopus
2-s2.0-85072983372