LIF measurement in a partially saturated and partially absorbed regime
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F24%3A00587821" target="_blank" >RIV/68081715:_____/24:00587821 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/24:00136528
Výsledek na webu
<a href="https://www.frontiersin.org/journals/physics/articles/10.3389/fphy.2024.1408078/full" target="_blank" >https://www.frontiersin.org/journals/physics/articles/10.3389/fphy.2024.1408078/full</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fphy.2024.1408078" target="_blank" >10.3389/fphy.2024.1408078</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LIF measurement in a partially saturated and partially absorbed regime
Popis výsledku v původním jazyce
The equations for the evaluation of Rayleigh-calibrated LIF measurements in a partially saturated regime when a detectable part of laser photons is absorbed in the sample, in other words of partially saturated fluorescence measurement with spatially dependent intensity of the excitation radiation, were summarized. LIF measurement evaluated by these equations was tested on free tellurium atoms present in an atmospheric pressure DBD. The results were in a good agreement with both the expected Te concentration and with the measured absorption of laser in the DBD, demonstrating a high reliability of absolute LIF measurements.
Název v anglickém jazyce
LIF measurement in a partially saturated and partially absorbed regime
Popis výsledku anglicky
The equations for the evaluation of Rayleigh-calibrated LIF measurements in a partially saturated regime when a detectable part of laser photons is absorbed in the sample, in other words of partially saturated fluorescence measurement with spatially dependent intensity of the excitation radiation, were summarized. LIF measurement evaluated by these equations was tested on free tellurium atoms present in an atmospheric pressure DBD. The results were in a good agreement with both the expected Te concentration and with the measured absorption of laser in the DBD, demonstrating a high reliability of absolute LIF measurements.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Frontiers in Physics
ISSN
2296-424X
e-ISSN
2296-424X
Svazek periodika
12
Číslo periodika v rámci svazku
JUL
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
1408078
Kód UT WoS článku
001274865900001
EID výsledku v databázi Scopus
2-s2.0-85199280973