Simultaneous quantification of JWH-018, JWH-073, and their metabolites (4-OH JWH-018, 3-OH JWH-073) in human plasma and urine samples by LC-MS/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F25%3A00601043" target="_blank" >RIV/68081715:_____/25:00601043 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1080/10826076.2024.2414026" target="_blank" >https://doi.org/10.1080/10826076.2024.2414026</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/10826076.2024.2414026" target="_blank" >10.1080/10826076.2024.2414026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simultaneous quantification of JWH-018, JWH-073, and their metabolites (4-OH JWH-018, 3-OH JWH-073) in human plasma and urine samples by LC-MS/MS
Popis výsledku v původním jazyce
This study aims to develop and validate a method for the simultaneous quantification of JWH-073, JWH-018, and their two main metabolites 3-OH JWH-073 and 4-OH JWH-018 in human blood and urine samples by using liquid chromatography combined with a mass spectrometer (LC-MS/MS). The method was validated according to current FDA and EMA guidelines and was tested on 10 urine samples from suspected synthetic cannabinoid abusers and 10 plasma samples from drug-free volunteers. Experimental data showed that the limits of detection (LOD) for the analytes were very low at 0.01 ng/mL in plasma samples and 0.003 ng/mL in urine samples. The limits of quantification (LLOQ) were 0.03 ng/mL in plasma samples and 0.01 ng/mL in urine samples. The linear correlation coefficients (R2) for these analytes ranged from 0.9914 to 0.9929 in plasma samples and 0.9820 to 0.9892 in urine samples. Among the 10 urine samples from suspected synthetic cannabinoid abusers, the parent JWH-073 and JWH-018 analytes were detected in six and three samples, with concentrations of 0.01 8.14 ng/mL and 7.16 17.50 ng/mL, respectively. At the same time, their two main metabolites, 3-OH JWH-073 and 4-OH JWH-018, were also found in the samples containing parent drugs, with concentrations of 32.13 84.24 ng/mL and 14.48-32.97 ng/mL, respectively. Three samples (T3, T5, and T6) contained only 4-OH JWH-018 metabolite (with concentrations of 25.69 51.87 ng/mL) and one sample (T10) contained only 3-OH JWH-073 metabolite (with concentration of 56.94 ng/mL) without the presence of their parent drugs. The plasma samples from drug-free volunteers were all negative for the analytes.
Název v anglickém jazyce
Simultaneous quantification of JWH-018, JWH-073, and their metabolites (4-OH JWH-018, 3-OH JWH-073) in human plasma and urine samples by LC-MS/MS
Popis výsledku anglicky
This study aims to develop and validate a method for the simultaneous quantification of JWH-073, JWH-018, and their two main metabolites 3-OH JWH-073 and 4-OH JWH-018 in human blood and urine samples by using liquid chromatography combined with a mass spectrometer (LC-MS/MS). The method was validated according to current FDA and EMA guidelines and was tested on 10 urine samples from suspected synthetic cannabinoid abusers and 10 plasma samples from drug-free volunteers. Experimental data showed that the limits of detection (LOD) for the analytes were very low at 0.01 ng/mL in plasma samples and 0.003 ng/mL in urine samples. The limits of quantification (LLOQ) were 0.03 ng/mL in plasma samples and 0.01 ng/mL in urine samples. The linear correlation coefficients (R2) for these analytes ranged from 0.9914 to 0.9929 in plasma samples and 0.9820 to 0.9892 in urine samples. Among the 10 urine samples from suspected synthetic cannabinoid abusers, the parent JWH-073 and JWH-018 analytes were detected in six and three samples, with concentrations of 0.01 8.14 ng/mL and 7.16 17.50 ng/mL, respectively. At the same time, their two main metabolites, 3-OH JWH-073 and 4-OH JWH-018, were also found in the samples containing parent drugs, with concentrations of 32.13 84.24 ng/mL and 14.48-32.97 ng/mL, respectively. Three samples (T3, T5, and T6) contained only 4-OH JWH-018 metabolite (with concentrations of 25.69 51.87 ng/mL) and one sample (T10) contained only 3-OH JWH-073 metabolite (with concentration of 56.94 ng/mL) without the presence of their parent drugs. The plasma samples from drug-free volunteers were all negative for the analytes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Liquid Chromatography & Related Technologies
ISSN
1082-6076
e-ISSN
1520-572X
Svazek periodika
48
Číslo periodika v rámci svazku
1-5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
19-27
Kód UT WoS článku
001346993000001
EID výsledku v databázi Scopus
2-s2.0-85209084281