MATERIALS SCIENCE BEAMLINE, ELETTRA TRIESTE - NEW INSTRUMENT FOR SURFACE SCIENCE.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081723%3A_____%2F01%3A07013279" target="_blank" >RIV/68081723:_____/01:07013279 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
MATERIALS SCIENCE BEAMLINE, ELETTRA TRIESTE - NEW INSTRUMENT FOR SURFACE SCIENCE.
Popis výsledku v původním jazyce
The Materials Science Beamline is attached to a bending magnet at synchrotron Elettra Trieste, Italy. The tuning range is from 35 to 800 eV with calculated spectral resolving power E/delta E better than 4000 in the whole range. The optical elements consist of a toroidal prefocusing mirror, polarization aperture, entrance slit, plane pre-mirror, single plane grating (blazed), spherical mirror, exit slit and toroidal refocusing mirror. The plane grating is operated in the fixed focus mode with Cff = 2.4.Energy scanning is performed by rotation of the plane grating and simultaneous translation and rotation of the plane pre-mirror. In the first tests, a resolving power of at least 4000 has been achieved at energies of 400 eV. The calculated photon flux atthe sample is compared with measured values. Various experimental chambers depending on experiments can be attached to the beamline (LEEM, ESCA).
Název v anglickém jazyce
MATERIALS SCIENCE BEAMLINE, ELETTRA TRIESTE - NEW INSTRUMENT FOR SURFACE SCIENCE.
Popis výsledku anglicky
The Materials Science Beamline is attached to a bending magnet at synchrotron Elettra Trieste, Italy. The tuning range is from 35 to 800 eV with calculated spectral resolving power E/delta E better than 4000 in the whole range. The optical elements consist of a toroidal prefocusing mirror, polarization aperture, entrance slit, plane pre-mirror, single plane grating (blazed), spherical mirror, exit slit and toroidal refocusing mirror. The plane grating is operated in the fixed focus mode with Cff = 2.4.Energy scanning is performed by rotation of the plane grating and simultaneous translation and rotation of the plane pre-mirror. In the first tests, a resolving power of at least 4000 has been achieved at energies of 400 eV. The calculated photon flux atthe sample is compared with measured values. Various experimental chambers depending on experiments can be attached to the beamline (LEEM, ESCA).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GV202%2F98%2FK002" target="_blank" >GV202/98/K002: Měřící stanice pro materiálový výzkum s použitím synchrotronového záření</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Conference Juniormat'01.
ISBN
80-214-1885-0
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
279-280
Název nakladatele
Ústav materiálového inženýrství F. Píška VUT FSI
Místo vydání
Brno
Místo konání akce
Brno [CZ]
Datum konání akce
19. 9. 2001
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—