Popis výsledku v původním jazyce
Creep response of ex-service austenitic steel was investigated at temperatures from 470 to 550°C and stresses from 80 to 120 MPa. The conditions lead to very low strain rates. Helicoid spring specimen technique and improved conventional creep tests wereused to record very low creep strains. Results were compared to creep curves obtained on the new steel of the same type under the same conditions. The creep behaviour of the ex-service steel was very similar to that of the new steels. No creep damage orconsiderable change of microstructure was detected during the service period of 65/,000/,hours. The helicoid spring specimen technique provides results compatible with that of conventional creep tests, but with superior accuracy with very low creep strains. The data can also be used in some special cases, where the creep strain itself is limiting the creep life of the part rather than creep failure.
Název v anglickém jazyce
Creep of Ex-service AISI-316H Steel at Very Low Strain Rates
Popis výsledku anglicky
Creep response of ex-service austenitic steel was investigated at temperatures from 470 to 550°C and stresses from 80 to 120 MPa. The conditions lead to very low strain rates. Helicoid spring specimen technique and improved conventional creep tests wereused to record very low creep strains. Results were compared to creep curves obtained on the new steel of the same type under the same conditions. The creep behaviour of the ex-service steel was very similar to that of the new steels. No creep damage orconsiderable change of microstructure was detected during the service period of 65/,000/,hours. The helicoid spring specimen technique provides results compatible with that of conventional creep tests, but with superior accuracy with very low creep strains. The data can also be used in some special cases, where the creep strain itself is limiting the creep life of the part rather than creep failure.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA200410701" target="_blank" >IAA200410701: Přechodové jevy při creepu za podmínek vedoucích k velmi malým rychlostem deformace.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Materials for Advanced Power Engineering 2010
ISBN
978-3-89336-685-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
142-149
Název nakladatele
Forschungszentrum Jülich GmbH
Místo vydání
Liege
Místo konání akce
Liege
Datum konání akce
27. 9. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—