Failure conditions from push-out tests of a steel-concrete joint: experimental results
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081723%3A_____%2F12%3A00370073" target="_blank" >RIV/68081723:_____/12:00370073 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.488-489.714" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.488-489.714</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.488-489.714" target="_blank" >10.4028/www.scientific.net/KEM.488-489.714</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Failure conditions from push-out tests of a steel-concrete joint: experimental results
Popis výsledku v původním jazyce
Steel-concrete joints can suffer from premature fail due to inadequate shear bond between the two surfaces. In this paper the shear bond strength between steel and self-compacting concrete (SCC) without mechanical shear connectors is evaluated through push-out tests. The test samples consist of two sandblasted steel plates (10 and 6 mm) and a concrete core, with connection between steel and concrete obtained by a 2-component epoxy resin, gritted with granulates. During the tests, the ultimate shear force is recorded as well as the slip between steel and concrete. All test members exhibited a concrete - adhesive failure, and indicate nominal shear bond stresses between 2.20 and 4.22 MPa. In addition, a substantial difference in measured shear bond stresses is found between the 6 and 10 mm steel plates, indicating unwanted secondary effects with the 6 mm plates. During testing, maximum slip values between 0.02 and 0.05 mm are recorded. In addition to the experimental tests, shear stress
Název v anglickém jazyce
Failure conditions from push-out tests of a steel-concrete joint: experimental results
Popis výsledku anglicky
Steel-concrete joints can suffer from premature fail due to inadequate shear bond between the two surfaces. In this paper the shear bond strength between steel and self-compacting concrete (SCC) without mechanical shear connectors is evaluated through push-out tests. The test samples consist of two sandblasted steel plates (10 and 6 mm) and a concrete core, with connection between steel and concrete obtained by a 2-component epoxy resin, gritted with granulates. During the tests, the ultimate shear force is recorded as well as the slip between steel and concrete. All test members exhibited a concrete - adhesive failure, and indicate nominal shear bond stresses between 2.20 and 4.22 MPa. In addition, a substantial difference in measured shear bond stresses is found between the 6 and 10 mm steel plates, indicating unwanted secondary effects with the 6 mm plates. During testing, maximum slip values between 0.02 and 0.05 mm are recorded. In addition to the experimental tests, shear stress
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JL - Únava materiálu a lomová mechanika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP108%2F10%2F2049" target="_blank" >GAP108/10/2049: Iniciace a šíření trhliny ze singulárních koncentrátorů napětí souvisejících s rozhraním</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Key Engineering Materials
ISSN
1013-9826
e-ISSN
—
Svazek periodika
488-489
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
714-717
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—