The Gurson-Tvergaard-Needleman model calibration from sub-size test specimens by size corresponding to the half of Charpy specimen
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081723%3A_____%2F14%3A00435307" target="_blank" >RIV/68081723:_____/14:00435307 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Gurson-Tvergaard-Needleman model calibration from sub-size test specimens by size corresponding to the half of Charpy specimen
Popis výsledku v původním jazyce
The paper deals with a utilization of miniaturized tensile specimens for purposes of local approach application from limited amount of test material. The motivation for application of those miniaturized specimens is the utilization of volume of test material corresponding to the half of Charpy specimen. The tensile testing of miniaturized specimens was conducted at room temperature in ductile regime of the Eurofer97 steel followed by detailed fractography and quantitative analysis of micromechanism of damage. The parameters of Gurson-Tvergaard-Needleman micromechanical model of ductile fracture were calibrated. Except for the slight differences in strength and deformation characteristics no other differences between two sizes of tensile specimens werefound. The calibrated sets of parameters of GTN model using the same element size were very similar. The application of different calibrated sets of GTN model parameters for simulation of damage in cracked specimen (R-curve) is sensitive
Název v anglickém jazyce
The Gurson-Tvergaard-Needleman model calibration from sub-size test specimens by size corresponding to the half of Charpy specimen
Popis výsledku anglicky
The paper deals with a utilization of miniaturized tensile specimens for purposes of local approach application from limited amount of test material. The motivation for application of those miniaturized specimens is the utilization of volume of test material corresponding to the half of Charpy specimen. The tensile testing of miniaturized specimens was conducted at room temperature in ductile regime of the Eurofer97 steel followed by detailed fractography and quantitative analysis of micromechanism of damage. The parameters of Gurson-Tvergaard-Needleman micromechanical model of ductile fracture were calibrated. Except for the slight differences in strength and deformation characteristics no other differences between two sizes of tensile specimens werefound. The calibrated sets of parameters of GTN model using the same element size were very similar. The application of different calibrated sets of GTN model parameters for simulation of damage in cracked specimen (R-curve) is sensitive
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JL - Únava materiálu a lomová mechanika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Determination of mechanical properties of materials by small punch and other miniature testing techniques
ISBN
978-80-260-6722-1
ISSN
—
e-ISSN
—
Počet stran výsledku
14
Strana od-do
368-381
Název nakladatele
Ocelot s.r.o
Místo vydání
Ostrava
Místo konání akce
Seggau
Datum konání akce
23. 9. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—