Comparison of fracture toughness values of normal and high strength concrete determined by three point bend and modified disk-shaped compact tension specimens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081723%3A_____%2F17%3A00479796" target="_blank" >RIV/68081723:_____/17:00479796 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3221/IGF-ESIS.42.07" target="_blank" >http://dx.doi.org/10.3221/IGF-ESIS.42.07</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3221/IGF-ESIS.42.07" target="_blank" >10.3221/IGF-ESIS.42.07</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of fracture toughness values of normal and high strength concrete determined by three point bend and modified disk-shaped compact tension specimens
Popis výsledku v původním jazyce
The modified disk shaped compact tension test is a configuration derived from standard compact tension test that is used for measuring fracture mechanical properties of primarily metallic materials. The compact tension configuration is commonly used for measurement fracture mechanical properties as e.g. fracture toughness, Young’s modulus, work of fracture etc. The modified compact tension tests imply significant modifications of the specimen morphology in order to avoid premature failure. The modified compact tension test is not proper for quasi-brittle materials due to its complicated shape (steel-concrete interface), but it is easily extracted from drill core and we do not need large amount of material for obtaining fracture properties as we need for e.g. three- or four- point bend test. Since it is a new test method, a wide range of tests is needed to be done before it can be applied. In the paper the selected outputs of the experiments performed on normal and high strength concrete will be processed and the values of fracture mechanical parameters will be discussed
Název v anglickém jazyce
Comparison of fracture toughness values of normal and high strength concrete determined by three point bend and modified disk-shaped compact tension specimens
Popis výsledku anglicky
The modified disk shaped compact tension test is a configuration derived from standard compact tension test that is used for measuring fracture mechanical properties of primarily metallic materials. The compact tension configuration is commonly used for measurement fracture mechanical properties as e.g. fracture toughness, Young’s modulus, work of fracture etc. The modified compact tension tests imply significant modifications of the specimen morphology in order to avoid premature failure. The modified compact tension test is not proper for quasi-brittle materials due to its complicated shape (steel-concrete interface), but it is easily extracted from drill core and we do not need large amount of material for obtaining fracture properties as we need for e.g. three- or four- point bend test. Since it is a new test method, a wide range of tests is needed to be done before it can be applied. In the paper the selected outputs of the experiments performed on normal and high strength concrete will be processed and the values of fracture mechanical parameters will be discussed
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20306 - Audio engineering, reliability analysis
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Frattura ed Integrita Strutturale
ISSN
1971-8993
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
42
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
10
Strana od-do
56-65
Kód UT WoS článku
000423952200007
EID výsledku v databázi Scopus
2-s2.0-85030781325