Methods of Conversion of Stability of Femtosecond Stabilized Mode-locked Laser to Optical Resonator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F09%3A00336313" target="_blank" >RIV/68081731:_____/09:00336313 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Methods of Conversion of Stability of Femtosecond Stabilized Mode-locked Laser to Optical Resonator
Popis výsledku v původním jazyce
In this work we propose three methods of a conversion of RF clock stability to the length precision using fs stabilized laser via Fabry-Perot by three proven conversion techniques. One mode stabilized lasers could provide optical frequency reference. Stability of such a laser could be transferred to length etalon represented by optical interferometer.We present using of Fabry-Perot interferometer as a length etalon referenced to fs stabilized optical comb. The train of femtosecond pulses produces equidistant optical frequencies separated by repetition frequency and shifted by an offset frequency. Both frequencies are stabilized according to widely used f-to-2f stabilization method to RF frequency standard, i.e. atomic clocks represented by GPS controlled signal with relative stability down to 10E-15.
Název v anglickém jazyce
Methods of Conversion of Stability of Femtosecond Stabilized Mode-locked Laser to Optical Resonator
Popis výsledku anglicky
In this work we propose three methods of a conversion of RF clock stability to the length precision using fs stabilized laser via Fabry-Perot by three proven conversion techniques. One mode stabilized lasers could provide optical frequency reference. Stability of such a laser could be transferred to length etalon represented by optical interferometer.We present using of Fabry-Perot interferometer as a length etalon referenced to fs stabilized optical comb. The train of femtosecond pulses produces equidistant optical frequencies separated by repetition frequency and shifted by an offset frequency. Both frequencies are stabilized according to widely used f-to-2f stabilization method to RF frequency standard, i.e. atomic clocks represented by GPS controlled signal with relative stability down to 10E-15.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EFTF - IFCS 2009
ISBN
978-1-4244-3510-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Los Alamitos
Místo konání akce
Besancon
Datum konání akce
20. 3. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000274814900153