Data Processing in Studying the Temporomandibular Joint, Using MR Imaging and Sonographic Techniques
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F09%3A00336796" target="_blank" >RIV/68081731:_____/09:00336796 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Data Processing in Studying the Temporomandibular Joint, Using MR Imaging and Sonographic Techniques
Popis výsledku v původním jazyce
The temporomandibular joint is one of the most complicated joints in the human body. Diagnosing its disorders is difficult because the pain is mistakenly taken for toothache, pain in the jaw bones, etc. The paper deals with a post-processing tomographicexamination of temporomandibular joint. An interesting post-processing method was used to increase the contrast related to relaxation time T2. Both increasing the contrast and enhancing the arthritic region were realized by processing two MR images in different echo-times. The enhancement rate is realized on the basis of subjective MR image evaluation by the surgeon. Magnetic resonance images (MRIs) are of very low resolution and contrast. An appropriate algorithm has been found, which consists of preprocessingthe image by a smoothing filter, focusing, and four-phase level set segmentation.
Název v anglickém jazyce
Data Processing in Studying the Temporomandibular Joint, Using MR Imaging and Sonographic Techniques
Popis výsledku anglicky
The temporomandibular joint is one of the most complicated joints in the human body. Diagnosing its disorders is difficult because the pain is mistakenly taken for toothache, pain in the jaw bones, etc. The paper deals with a post-processing tomographicexamination of temporomandibular joint. An interesting post-processing method was used to increase the contrast related to relaxation time T2. Both increasing the contrast and enhancing the arthritic region were realized by processing two MR images in different echo-times. The enhancement rate is realized on the basis of subjective MR image evaluation by the surgeon. Magnetic resonance images (MRIs) are of very low resolution and contrast. An appropriate algorithm has been found, which consists of preprocessingthe image by a smoothing filter, focusing, and four-phase level set segmentation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F07%2F1086" target="_blank" >GA102/07/1086: Specifické zobrazovací metody pracující na bázi magnetické resonance a ultrazvuku pro studium čelistních kloubů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
DSP 2009 - 16th International Conference on Digital Signal processing
ISBN
978-1-4244-3297-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
HOU
Místo vydání
Patras
Místo konání akce
Santorini
Datum konání akce
5. 7. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—