Narrow-selection bandwith of femtosecond laser comb with application to changes in optical path distance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F10%3A00352220" target="_blank" >RIV/68081731:_____/10:00352220 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Narrow-selection bandwith of femtosecond laser comb with application to changes in optical path distance
Popis výsledku v původním jazyce
In this contribution we propose a scheme of Fabry-Perot interferometer measuring the absolute distance in atmosferic conditions using a femtosecond laser comb. The spacing of mirrors of the Fabry-Perot interferometer represents the length standard referenced to stable optical frequency of the femtosecond mode-locked laser. With the help of highly selective optical filter it is possible to get only a few of separate spectral components. By tuning and locking of the Fabry-Perot cavity to a selected singlecomponent it is possible to get a mechanical length standard with the uncertainty of the repetition frequency of the femtosecond laser. If the interferometer measures distance in atmospheric conditions, the absolute value of the laser wavelength fluctuates with a refractive index of air. Compairing the measurement in evacuated chamber with measurement in ambient air leads to enhanced precision in measurement of refrective index of air.
Název v anglickém jazyce
Narrow-selection bandwith of femtosecond laser comb with application to changes in optical path distance
Popis výsledku anglicky
In this contribution we propose a scheme of Fabry-Perot interferometer measuring the absolute distance in atmosferic conditions using a femtosecond laser comb. The spacing of mirrors of the Fabry-Perot interferometer represents the length standard referenced to stable optical frequency of the femtosecond mode-locked laser. With the help of highly selective optical filter it is possible to get only a few of separate spectral components. By tuning and locking of the Fabry-Perot cavity to a selected singlecomponent it is possible to get a mechanical length standard with the uncertainty of the repetition frequency of the femtosecond laser. If the interferometer measures distance in atmospheric conditions, the absolute value of the laser wavelength fluctuates with a refractive index of air. Compairing the measurement in evacuated chamber with measurement in ambient air leads to enhanced precision in measurement of refrective index of air.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Optical Micro- and Nanometrology III (Proceedings of SPIE Vol. 7718)
ISBN
978-0-8194-8191-7
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Brussels
Datum konání akce
13. 4. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000285182000034