An experimental study of turbulent Rayleigh-Benard convection (RBC) and of the influence of various experimental aspects is presented and comparison with similar experiments discussed. We use a cylindrical cell 0.3 m both in diameter and height, designedto minimize the influence of its structure on the convective flow of cryogenic He-4 gas of Prandtl number Pr approximate to 1. We measure the dependence of Nusselt (Nu) versus Rayleigh number (Ra) at high Ra and discuss various corrections that might beapplicable to the raw data. For 7.2 x 10(6) <= Ra less than or similar to 10(11) our data agree with suitably corrected data from similar cryogenic experiments and are consistent with Nu proportional to Ra-2/7. On approaching Ra approximate to 10(11) our data display a crossover to Nu proportional to Ra-1/3 that approximately holds up to Ra congruent to 4.6 x 10(13). We show that differences in Nu(Ra) scaling observed in similar RBC experiments for Ra greater than or similar to 10(11) c
Název v anglickém jazyce
Comments on heat trasfer efficiency in cryogenic helium turbulent Rayleigh-Bénard convection
Popis výsledku anglicky
An experimental study of turbulent Rayleigh-Benard convection (RBC) and of the influence of various experimental aspects is presented and comparison with similar experiments discussed. We use a cylindrical cell 0.3 m both in diameter and height, designedto minimize the influence of its structure on the convective flow of cryogenic He-4 gas of Prandtl number Pr approximate to 1. We measure the dependence of Nusselt (Nu) versus Rayleigh number (Ra) at high Ra and discuss various corrections that might beapplicable to the raw data. For 7.2 x 10(6) <= Ra less than or similar to 10(11) our data agree with suitably corrected data from similar cryogenic experiments and are consistent with Nu proportional to Ra-2/7. On approaching Ra approximate to 10(11) our data display a crossover to Nu proportional to Ra-1/3 that approximately holds up to Ra congruent to 4.6 x 10(13). We show that differences in Nu(Ra) scaling observed in similar RBC experiments for Ra greater than or similar to 10(11) c
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KJB200650902" target="_blank" >KJB200650902: Objasnění zásadních otázek turbulentní konvekce</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Physics: Conference Series
ISSN
1742-6588
e-ISSN
—
Svazek periodika
318
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
000301224000012
EID výsledku v databázi Scopus
—