Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F13%3A00421676" target="_blank" >RIV/68081731:_____/13:00421676 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/13:00060567 RIV/00216305:26220/13:PU102196
Výsledek na webu
<a href="http://dx.doi.org/10.1088/0967-3334/34/2/151" target="_blank" >http://dx.doi.org/10.1088/0967-3334/34/2/151</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0967-3334/34/2/151" target="_blank" >10.1088/0967-3334/34/2/151</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents
Popis výsledku v původním jazyce
Dynamic contrast-enhanced ultrasound (DCE-US) imaging is a promising diagnostic method, which enables the evaluation of tissue perfusion via different parameters. The mean transit time and time-to-peak parameters are the main time parameters and their values depend on the model used for the approximation of the noisy perfusion curves. In this paper, we described a new comparison of different perfusion models using a tissue mimicking phantom. The following models were compared: log-normal, lagged, Erlang, Gamma and the local density random walk model. We discovered that the mean-square error is not the best criterion for model evaluation. More important is the comparison between the estimated time perfusion parameters and the physical parameters of thedeveloped tissue mimicking phantom. Based on the statistical analysis, we can suggest that for the DCE-US perfusion analysis more models should be used, excluding the log-normal model, which gives the highest error of mean transit time va
Název v anglickém jazyce
Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents
Popis výsledku anglicky
Dynamic contrast-enhanced ultrasound (DCE-US) imaging is a promising diagnostic method, which enables the evaluation of tissue perfusion via different parameters. The mean transit time and time-to-peak parameters are the main time parameters and their values depend on the model used for the approximation of the noisy perfusion curves. In this paper, we described a new comparison of different perfusion models using a tissue mimicking phantom. The following models were compared: log-normal, lagged, Erlang, Gamma and the local density random walk model. We discovered that the mean-square error is not the best criterion for model evaluation. More important is the comparison between the estimated time perfusion parameters and the physical parameters of thedeveloped tissue mimicking phantom. Based on the statistical analysis, we can suggest that for the DCE-US perfusion analysis more models should be used, excluding the log-normal model, which gives the highest error of mean transit time va
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Measurement
ISSN
0967-3334
e-ISSN
—
Svazek periodika
34
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
151-162
Kód UT WoS článku
000314287500004
EID výsledku v databázi Scopus
—