New vertical cryostat for the high field superconducting magnet test station at CERN
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F14%3A00429815" target="_blank" >RIV/68081731:_____/14:00429815 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.4860706" target="_blank" >http://dx.doi.org/10.1063/1.4860706</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4860706" target="_blank" >10.1063/1.4860706</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New vertical cryostat for the high field superconducting magnet test station at CERN
Popis výsledku v původním jazyce
In the framework of the R&D program for new superconducting magnets for the Large Hadron Collider accelerator upgrades, CERN is building a new vertical test station to test high field superconducting magnets of unprecedented large size. This facility will allow testing of magnets by vertical insertion in a pressurized liquid helium bath, cooled to a controlled temperature between 4.2 K and 1.9 K. The dimensions of the cryostat will allow testing magnets of up to 2.5 m in length with a maximum diameter of 1.5 m and a mass of 15 tons. To allow for a faster insertion and removal of the magnets and reducing the risk of helium leaks, all cryogenics supply lines are foreseen to remain permanently connected to the cryostat. A specifically designed 100 W heatexchanger is integrated in the cryostat helium vessel for a controlled cooling of the magnet from 4.2 K down to 1.9 K in a 3 m3 helium bath. This paper describes the cryostat and its main functions, focusing on features specifically devel
Název v anglickém jazyce
New vertical cryostat for the high field superconducting magnet test station at CERN
Popis výsledku anglicky
In the framework of the R&D program for new superconducting magnets for the Large Hadron Collider accelerator upgrades, CERN is building a new vertical test station to test high field superconducting magnets of unprecedented large size. This facility will allow testing of magnets by vertical insertion in a pressurized liquid helium bath, cooled to a controlled temperature between 4.2 K and 1.9 K. The dimensions of the cryostat will allow testing magnets of up to 2.5 m in length with a maximum diameter of 1.5 m and a mass of 15 tons. To allow for a faster insertion and removal of the magnets and reducing the risk of helium leaks, all cryogenics supply lines are foreseen to remain permanently connected to the cryostat. A specifically designed 100 W heatexchanger is integrated in the cryostat helium vessel for a controlled cooling of the magnet from 4.2 K down to 1.9 K in a 3 m3 helium bath. This paper describes the cryostat and its main functions, focusing on features specifically devel
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advances in Cryogenic Engineering. Transactions of the Cryogenic Engineering Conference - CEC
ISBN
978-0-7354-1201-9
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
8
Strana od-do
229-236
Název nakladatele
American Institute of Physics
Místo vydání
Melville, New York
Místo konání akce
Anchorage, Alaska
Datum konání akce
17. 6. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000343409400031