Název v původním jazyce
Design and Testing of Low Temperature Part of an UHV ? SPM Microscope
Popis výsledku v původním jazyce
We have developed low temperature part of an ultra high vacuum scanning probe microscope (UHV-SPM) working at variable temperature within the range from 20 K to 700 K. To achieve the required temperature range, a flow cooling system using cryogenic helium (approximately 5 K) as a coolant was designed. The system consists of a flow cryostat and a flexible low-loss transfer line connecting a Dewar vessel with the flow cryostat. We have also tested liquid nitrogen (approximately 77 K) as an alternative low-cost coolant. Using nitrogen, the microscope can operate at temperatures of about 100 K and higher. As the flow of the coolant through the cryostat can cause thermally induced two-phase flow fluctuations resulting in instability in temperatures, preliminary tests were done in order to find ways of avoiding the temperature oscillations and optimising the cooling process.
Název v anglickém jazyce
Design and Testing of Low Temperature Part of an UHV ? SPM Microscope
Popis výsledku anglicky
We have developed low temperature part of an ultra high vacuum scanning probe microscope (UHV-SPM) working at variable temperature within the range from 20 K to 700 K. To achieve the required temperature range, a flow cooling system using cryogenic helium (approximately 5 K) as a coolant was designed. The system consists of a flow cryostat and a flexible low-loss transfer line connecting a Dewar vessel with the flow cryostat. We have also tested liquid nitrogen (approximately 77 K) as an alternative low-cost coolant. Using nitrogen, the microscope can operate at temperatures of about 100 K and higher. As the flow of the coolant through the cryostat can cause thermally induced two-phase flow fluctuations resulting in instability in temperatures, preliminary tests were done in order to find ways of avoiding the temperature oscillations and optimising the cooling process.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Cryogenics 2014. The 13th IIR International Conference Proceedings
ISBN
978-2-36215-002-9
ISSN
0151-1637
e-ISSN
—
Počet stran výsledku
6
Strana od-do
324-329
Název nakladatele
Icaris
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
7. 4. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000346089100052