Optical Frequency References for Laser Interferometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F14%3A00441272" target="_blank" >RIV/68081731:_____/14:00441272 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1117/12.2086262" target="_blank" >http://dx.doi.org/10.1117/12.2086262</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2086262" target="_blank" >10.1117/12.2086262</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optical Frequency References for Laser Interferometry
Popis výsledku v původním jazyce
Optical frequency references for laser standards based on molecular iodine absorption cells represent one of the most used tool for frequency stabilization of lasers operating in a visible spectral range. In the industry oriented laser measurements and similar laser interferometry applications performed at atmospheric conditions, a refractive index of air plays a role of main uncertainty contributor. In these cases there is no need to use technologically complicated and expensive iodine references madeof pure fused silica with precise pressure control of absorpbing media. A set of iodine cells made of borosilicate glass was filled with certain amount of absorbing media to define the saturation point of iodine inside. A combination of these two approaches (pyrex material and controlled saturation pressure of iodine) allows us to simplify the laser stabilization setup (there is no need of additional iodine pressure level control) and reduce the overall reference?s costs with ensuring of
Název v anglickém jazyce
Optical Frequency References for Laser Interferometry
Popis výsledku anglicky
Optical frequency references for laser standards based on molecular iodine absorption cells represent one of the most used tool for frequency stabilization of lasers operating in a visible spectral range. In the industry oriented laser measurements and similar laser interferometry applications performed at atmospheric conditions, a refractive index of air plays a role of main uncertainty contributor. In these cases there is no need to use technologically complicated and expensive iodine references madeof pure fused silica with precise pressure control of absorpbing media. A set of iodine cells made of borosilicate glass was filled with certain amount of absorbing media to define the saturation point of iodine inside. A combination of these two approaches (pyrex material and controlled saturation pressure of iodine) allows us to simplify the laser stabilization setup (there is no need of additional iodine pressure level control) and reduce the overall reference?s costs with ensuring of
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Optics and Measurement Conference 2014 (Proceedings of SPIE 9442)
ISBN
9781628415575
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
"94420F: 1"-"6"
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Liberec
Datum konání akce
7. 10. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—