Multichannel QRS Morphology Clustering - Data Preprocessing for Ultra-High-Frequency ECG Analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F15%3A00452154" target="_blank" >RIV/68081731:_____/15:00452154 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/15:PU120337
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Multichannel QRS Morphology Clustering - Data Preprocessing for Ultra-High-Frequency ECG Analysis
Popis výsledku v původním jazyce
Ultra-high-frequency ECG (UHF-ECG) in a range of 500?1,000 Hz has been tested as a new information source for analysis of left-ventricle dyssynchrony and other myocardial abnormalities. The power of UHF signals is extremely low, for which reason an averaging technique is used to improve signal-to-noise ratio. Since ventricle dyssynchrony is different for various QRS complex types, the detected QRS complexes must be clustered into morphology groups prior to averaging. Here, we present a fully-automated method for clustering. The first goal of the method is to separate previously detected QRS complexes into different morphology groups. The second goal is to precisely fit the QRS annotation marks to the exact same position against the QRS shape. The method is based on the Pearson correlation and is optimized for parallel processing. In our application with UHF-ECG data the number of detected groups was 3.24 3.41 (mean and standard deviation over 1,030 records). The method can be used in o
Název v anglickém jazyce
Multichannel QRS Morphology Clustering - Data Preprocessing for Ultra-High-Frequency ECG Analysis
Popis výsledku anglicky
Ultra-high-frequency ECG (UHF-ECG) in a range of 500?1,000 Hz has been tested as a new information source for analysis of left-ventricle dyssynchrony and other myocardial abnormalities. The power of UHF signals is extremely low, for which reason an averaging technique is used to improve signal-to-noise ratio. Since ventricle dyssynchrony is different for various QRS complex types, the detected QRS complexes must be clustered into morphology groups prior to averaging. Here, we present a fully-automated method for clustering. The first goal of the method is to separate previously detected QRS complexes into different morphology groups. The second goal is to precisely fit the QRS annotation marks to the exact same position against the QRS shape. The method is based on the Pearson correlation and is optimized for parallel processing. In our application with UHF-ECG data the number of detected groups was 3.24 3.41 (mean and standard deviation over 1,030 records). The method can be used in o
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 3rd International Congress on Cardiovascular Technologies
ISBN
978-989-758-160-1
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
11-19
Název nakladatele
Polytechnic Institute of Setúbal
Místo vydání
Lisbon
Místo konání akce
Lisbon
Datum konání akce
16. 11. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—