Comparison of arterial input function models for small-animal ultrasound perfusion imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F16%3A00466798" target="_blank" >RIV/68081731:_____/16:00466798 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/16:PU120750
Výsledek na webu
<a href="http://ieeexplore.ieee.org/abstract/document/7728503/" target="_blank" >http://ieeexplore.ieee.org/abstract/document/7728503/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ULTSYM.2016.7728503" target="_blank" >10.1109/ULTSYM.2016.7728503</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of arterial input function models for small-animal ultrasound perfusion imaging
Popis výsledku v původním jazyce
Quantitative ultrasound perfusion imaging is used to estimate tissue perfusion parameters, such as blood flow, blood volume and mean transit time. The bolus & burst method is one possible approach to quantitative ultrasound perfusion imaging. It is based on a pharmacokinetic model where the tissue intensity curves are modeled as a convolution of an arterial input function (AIF) and an impulse residue function. Two AIF models have been presented for the bolus & burst method so far based on two lognormal and three gamma variate functions. The aim of this contribution is to suggest other alternative AIF models and test their suitability for the bolus & burst method for small-animal applications by comparison with measured AIFs.
Název v anglickém jazyce
Comparison of arterial input function models for small-animal ultrasound perfusion imaging
Popis výsledku anglicky
Quantitative ultrasound perfusion imaging is used to estimate tissue perfusion parameters, such as blood flow, blood volume and mean transit time. The bolus & burst method is one possible approach to quantitative ultrasound perfusion imaging. It is based on a pharmacokinetic model where the tissue intensity curves are modeled as a convolution of an arterial input function (AIF) and an impulse residue function. Two AIF models have been presented for the bolus & burst method so far based on two lognormal and three gamma variate functions. The aim of this contribution is to suggest other alternative AIF models and test their suitability for the bolus & burst method for small-animal applications by comparison with measured AIFs.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1212" target="_blank" >LO1212: ALISI - Centrum pokročilých diagnostických metod a technologií</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE International Ultrasonics Symposium (IUS) 2016
ISBN
978-1-4673-9897-8
ISSN
1948-5727
e-ISSN
—
Počet stran výsledku
4
Strana od-do
"7728503:1"-"4"
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Tours
Datum konání akce
18. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000387497400130