Iodine Absorption Cells Quality Measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F16%3A00467377" target="_blank" >RIV/68081731:_____/16:00467377 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/7477845/?section=abstract" target="_blank" >http://ieeexplore.ieee.org/document/7477845/?section=abstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EFTF.2016.7477827" target="_blank" >10.1109/EFTF.2016.7477827</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Iodine Absorption Cells Quality Measurements
Popis výsledku v původním jazyce
This work is oriented to comparison of methods for iodine absorption cells quality evaluation. Optical frequency references based on molecular iodine represent one of the most used references for stabilizion of laser standards working at visible spectral range. Unfortunately iodine is a media with very high sensitivity to contamination so the chemical purity of iodine cells must be preciselly controlled. Traditional methods for iodine absorption cells quality checking have several difficulties and disadvantages, these problems complicate their common using in labs. Due to this reason we propose an alternative method of spectral linewidths measurement, which overcomes these difficulties of traditionally used approaches and which serves as a tool for iodine cells quality evaluation. In this work we present the results of comparison of two laser induced fluorescence setups (with and without the compensation for the laser source spectral mode-hops) with proposed method of selected hyperfine transition linewidth measurements and we discuss advantages and limitations of these methods for practical using.
Název v anglickém jazyce
Iodine Absorption Cells Quality Measurements
Popis výsledku anglicky
This work is oriented to comparison of methods for iodine absorption cells quality evaluation. Optical frequency references based on molecular iodine represent one of the most used references for stabilizion of laser standards working at visible spectral range. Unfortunately iodine is a media with very high sensitivity to contamination so the chemical purity of iodine cells must be preciselly controlled. Traditional methods for iodine absorption cells quality checking have several difficulties and disadvantages, these problems complicate their common using in labs. Due to this reason we propose an alternative method of spectral linewidths measurement, which overcomes these difficulties of traditionally used approaches and which serves as a tool for iodine cells quality evaluation. In this work we present the results of comparison of two laser induced fluorescence setups (with and without the compensation for the laser source spectral mode-hops) with proposed method of selected hyperfine transition linewidth measurements and we discuss advantages and limitations of these methods for practical using.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
European Frequency and Time Forum (EFTF) 2016
ISBN
978-1-5090-0720-2
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
York
Datum konání akce
4. 4. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000386307700090