Effect of gold coating on emissivity and absorptivity of Ti-6Al-4V alloy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F17%3A00478277" target="_blank" >RIV/68081731:_____/17:00478277 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.18462/iir.cryo.2017.0102" target="_blank" >http://dx.doi.org/10.18462/iir.cryo.2017.0102</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.18462/iir.cryo.2017.0102" target="_blank" >10.18462/iir.cryo.2017.0102</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of gold coating on emissivity and absorptivity of Ti-6Al-4V alloy
Popis výsledku v původním jazyce
The article provides experimental analysis of total hemispherical emissivity and absorptivity of Ti-6Al-4V alloy before and after deposition of 1-2 .pí.m gold layer. We measured their dependences on the temperature of thermal radiation (varying from 20 K to 320 K) and confronted these results with mechanically polished copper, i.e. with material known for extremely low emissivity and absorptivity. Galvanic deposition of pure gold resulted in significant lowering of original emissivity of Ti-6Al-4V bare surfaces from 15.8 percent to 3.4 percent at 300 K and from 4.1 percent to 1.1 percent at 20 K. Our findings about thermal-radiative properties have practical relevance for an improvement of a low temperature part of an ultra-high vacuum scanning probe microscopen(UHV-SPM) designed by our group and could also be useful for other applications and low temperature systems.
Název v anglickém jazyce
Effect of gold coating on emissivity and absorptivity of Ti-6Al-4V alloy
Popis výsledku anglicky
The article provides experimental analysis of total hemispherical emissivity and absorptivity of Ti-6Al-4V alloy before and after deposition of 1-2 .pí.m gold layer. We measured their dependences on the temperature of thermal radiation (varying from 20 K to 320 K) and confronted these results with mechanically polished copper, i.e. with material known for extremely low emissivity and absorptivity. Galvanic deposition of pure gold resulted in significant lowering of original emissivity of Ti-6Al-4V bare surfaces from 15.8 percent to 3.4 percent at 300 K and from 4.1 percent to 1.1 percent at 20 K. Our findings about thermal-radiative properties have practical relevance for an improvement of a low temperature part of an ultra-high vacuum scanning probe microscopen(UHV-SPM) designed by our group and could also be useful for other applications and low temperature systems.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
14th Cryogenics 2017. IIR International Conference. Proceedings
ISBN
978-2-36215-022-7
ISSN
0151-1637
e-ISSN
—
Počet stran výsledku
6