Wavelength dependent characterization of a multimode fibre endoscope
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F19%3A00509516" target="_blank" >RIV/68081731:_____/19:00509516 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.osapublishing.org/oe/fulltext.cfm?uri=oe-27-20-28239&id=420761" target="_blank" >https://www.osapublishing.org/oe/fulltext.cfm?uri=oe-27-20-28239&id=420761</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/OE.27.028239" target="_blank" >10.1364/OE.27.028239</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Wavelength dependent characterization of a multimode fibre endoscope
Popis výsledku v původním jazyce
Multimode fibres have recently shown promise as miniature endoscopic probes. When used for non-linear microscopy, the bandwidth of the imaging system limits the ability to focus light from broadband pulsed lasers as well as the possibility of wavelength tuning during the imaging. We demonstrate that the bandwidth is limited by the dispersion of the off-axis hologram displayed on the SLM, which can be corrected for, and by the limited bandwidth of the fibre itself. The selection of the fibre is therefore crucial for these experiments. In addition, we show that a standard prism pulse compressor is sufficient for material dispersion compensation for multi-photon imaging with a fibre endoscope.
Název v anglickém jazyce
Wavelength dependent characterization of a multimode fibre endoscope
Popis výsledku anglicky
Multimode fibres have recently shown promise as miniature endoscopic probes. When used for non-linear microscopy, the bandwidth of the imaging system limits the ability to focus light from broadband pulsed lasers as well as the possibility of wavelength tuning during the imaging. We demonstrate that the bandwidth is limited by the dispersion of the off-axis hologram displayed on the SLM, which can be corrected for, and by the limited bandwidth of the fibre itself. The selection of the fibre is therefore crucial for these experiments. In addition, we show that a standard prism pulse compressor is sufficient for material dispersion compensation for multi-photon imaging with a fibre endoscope.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Optics Express
ISSN
1094-4087
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
20
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
15
Strana od-do
28239-28253
Kód UT WoS článku
000488282800093
EID výsledku v databázi Scopus
2-s2.0-85072710865