Measurement of the Hydrogen Cyanide Absorption Lines' Centers with the Potential for Mise en Pratique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F21%3A00552425" target="_blank" >RIV/68081731:_____/21:00552425 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9604261" target="_blank" >https://ieeexplore.ieee.org/document/9604261</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EFTF/IFCS52194.2021.9604261" target="_blank" >10.1109/EFTF/IFCS52194.2021.9604261</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of the Hydrogen Cyanide Absorption Lines' Centers with the Potential for Mise en Pratique
Popis výsledku v původním jazyce
We built a linear absorption spectroscopy setup to measure hydrogen cyanide (H13C14N) 2?3 rotational-vibrational band. The laser's frequency was locked to the minimum of the absorption line by using the 1f technique. We used a commercially available lock-in amplifier combined with a custom-made PID controller allowing for the short-term frequency stability of about 10-10. The laser frequency was determined by measuring the beat-note between the laser and the optical frequency comb. The laser was locked to each absorption line for about 8 hours and the final time record allowed us to determine the absorption line central frequency with the uncertainty of about 40 kHz. This shows significant improvement compared to the data already available for HCN. Our work can potentially lead to the acceptance of HCN for Mise en Pratique (MeP), which means that laser locked to one of the HCN lines can become the official source of the one-meter unit.
Název v anglickém jazyce
Measurement of the Hydrogen Cyanide Absorption Lines' Centers with the Potential for Mise en Pratique
Popis výsledku anglicky
We built a linear absorption spectroscopy setup to measure hydrogen cyanide (H13C14N) 2?3 rotational-vibrational band. The laser's frequency was locked to the minimum of the absorption line by using the 1f technique. We used a commercially available lock-in amplifier combined with a custom-made PID controller allowing for the short-term frequency stability of about 10-10. The laser frequency was determined by measuring the beat-note between the laser and the optical frequency comb. The laser was locked to each absorption line for about 8 hours and the final time record allowed us to determine the absorption line central frequency with the uncertainty of about 40 kHz. This shows significant improvement compared to the data already available for HCN. Our work can potentially lead to the acceptance of HCN for Mise en Pratique (MeP), which means that laser locked to one of the HCN lines can become the official source of the one-meter unit.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2021 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS). Proceedings
ISBN
978-1-6654-3935-0
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
(2021)
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
online
Datum konání akce
7. 7. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000784693000032