Endoscopic Imaging Using a Multimode Optical Fibre Calibrated with Multiple Internal References
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F22%3A00552078" target="_blank" >RIV/68081731:_____/22:00552078 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2304-6732/9/1/37" target="_blank" >https://www.mdpi.com/2304-6732/9/1/37</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/photonics9010037" target="_blank" >10.3390/photonics9010037</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Endoscopic Imaging Using a Multimode Optical Fibre Calibrated with Multiple Internal References
Popis výsledku v původním jazyce
The interferometric acquisition of the transmission matrix (TM) of a multimode optical fibre (MMF), which is at the heart of multimode fibre-based endoscopic imaging methods, requires using a reference beam. Attempts to use an internal reference, that is to provide the reference in a common pathway geometry through the MMF itself, lead to a speckled reference intensity and consequential occurrence of “blind spots” - locations where insufficient optical power in the reference wave inflicts strong measurement errors. Here we show that combining a relatively small number of TMs, which are measured using different internal references, facilitates a complete elimination of blind spots, and thereby a significant enhancement of the imaging quality.
Název v anglickém jazyce
Endoscopic Imaging Using a Multimode Optical Fibre Calibrated with Multiple Internal References
Popis výsledku anglicky
The interferometric acquisition of the transmission matrix (TM) of a multimode optical fibre (MMF), which is at the heart of multimode fibre-based endoscopic imaging methods, requires using a reference beam. Attempts to use an internal reference, that is to provide the reference in a common pathway geometry through the MMF itself, lead to a speckled reference intensity and consequential occurrence of “blind spots” - locations where insufficient optical power in the reference wave inflicts strong measurement errors. Here we show that combining a relatively small number of TMs, which are measured using different internal references, facilitates a complete elimination of blind spots, and thereby a significant enhancement of the imaging quality.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Photonics
ISSN
2304-6732
e-ISSN
2304-6732
Svazek periodika
9
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
37
Kód UT WoS článku
000759106500001
EID výsledku v databázi Scopus
2-s2.0-85123507712