The Effect of Decreasing Aperture Diameter on Signal Transmission from the Scintillator to the Photomultiplier Tube Over a Wide Energy Range
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F24%3A00618940" target="_blank" >RIV/68081731:_____/24:00618940 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/26722445:_____/24:N0000070
Výsledek na webu
<a href="https://www.ej-physics.org/index.php/ejphysics/article/view/344" target="_blank" >https://www.ej-physics.org/index.php/ejphysics/article/view/344</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.24018/ejphysics.2024.6.5.344" target="_blank" >10.24018/ejphysics.2024.6.5.344</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effect of Decreasing Aperture Diameter on Signal Transmission from the Scintillator to the Photomultiplier Tube Over a Wide Energy Range
Popis výsledku v původním jazyce
In this paper, we study the effect of decreasing aperture diameter on signal transmission from the scintillator to the PMT. The apertures have been inserted directly between the scintillator and the photomultiplier. Three different aperture diameters have been used over a wide energy range. A newly developed fast digital spectrometer has been utilized for experimental measurement in the radial channel of the VR-1 research reactor. The detector signals with and without inserted apertures have been measured and evaluated. The aim of our research was to determine the effect of the apertures on the spectral quality, energy range and the evaluated physical quantities.
Název v anglickém jazyce
The Effect of Decreasing Aperture Diameter on Signal Transmission from the Scintillator to the Photomultiplier Tube Over a Wide Energy Range
Popis výsledku anglicky
In this paper, we study the effect of decreasing aperture diameter on signal transmission from the scintillator to the PMT. The apertures have been inserted directly between the scintillator and the photomultiplier. Three different aperture diameters have been used over a wide energy range. A newly developed fast digital spectrometer has been utilized for experimental measurement in the radial channel of the VR-1 research reactor. The detector signals with and without inserted apertures have been measured and evaluated. The aim of our research was to determine the effect of the apertures on the spectral quality, energy range and the evaluated physical quantities.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal of Applied Physics
ISSN
2684-4451
e-ISSN
2684-4451
Svazek periodika
6
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
12-17