Focused ultrasound-induced blood-brain barrier opening: A comparative analysis of permeability quantification based on Ktrans and PS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F25%3A00619015" target="_blank" >RIV/68081731:_____/25:00619015 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/25:00143801 RIV/00216305:26220/26:0197784
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1002/mrm.30446" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/mrm.30446</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/mrm.30446" target="_blank" >10.1002/mrm.30446</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Focused ultrasound-induced blood-brain barrier opening: A comparative analysis of permeability quantification based on Ktrans and PS
Popis výsledku v původním jazyce
Purpose: Focused ultrasound-induced blood-brain barrier (BBB) opening is a promising method for neurotherapeutic delivery. The standard for quantifying induced BBB permeability is the Ktrans parameter, which reflects both permeability and plasma flow. The influence of plasma flow can be eliminated by estimating the PS parameter. However, this parameter has been largely unexplored in this application. This study aims to compare permeability estimates based on Ktrans and PS in focused ultrasound-induced BBB opening experiments. Methods: We used the extended Tofts model (ETM) and the two-compartment exchange model (2CXM) to estimate Ktrans and PS parameters, respectively. Permeability estimates were compared using simulated concentration curves, simulated DCE-MRI data, and real datasets. We explored the influence of spatially-regularized model fitting on the results. Results: For opened BBB, Ktrans was minimally influenced by plasma flow under the tested conditions. However, fitting the ETM often introduced outliers in Ktrans estimates in regions with closed BBB. The 2CXM outperformed the ETM at high signal-to-noise ratios, but its higher complexity led to lower precision at low signal-to-noise ratios. Both these issues were successfully compensated by spatially-regularized model fitting. Conclusion: Both Ktrans and PS seem to be eligible options for the quantification of BBB opening, and the correct choice depends on the specifics of the acquired DCE-MRI data. Additionally, spatial regularization has demonstrated its importance in enhancing the accuracy and reproducibility of results for both models.
Název v anglickém jazyce
Focused ultrasound-induced blood-brain barrier opening: A comparative analysis of permeability quantification based on Ktrans and PS
Popis výsledku anglicky
Purpose: Focused ultrasound-induced blood-brain barrier (BBB) opening is a promising method for neurotherapeutic delivery. The standard for quantifying induced BBB permeability is the Ktrans parameter, which reflects both permeability and plasma flow. The influence of plasma flow can be eliminated by estimating the PS parameter. However, this parameter has been largely unexplored in this application. This study aims to compare permeability estimates based on Ktrans and PS in focused ultrasound-induced BBB opening experiments. Methods: We used the extended Tofts model (ETM) and the two-compartment exchange model (2CXM) to estimate Ktrans and PS parameters, respectively. Permeability estimates were compared using simulated concentration curves, simulated DCE-MRI data, and real datasets. We explored the influence of spatially-regularized model fitting on the results. Results: For opened BBB, Ktrans was minimally influenced by plasma flow under the tested conditions. However, fitting the ETM often introduced outliers in Ktrans estimates in regions with closed BBB. The 2CXM outperformed the ETM at high signal-to-noise ratios, but its higher complexity led to lower precision at low signal-to-noise ratios. Both these issues were successfully compensated by spatially-regularized model fitting. Conclusion: Both Ktrans and PS seem to be eligible options for the quantification of BBB opening, and the correct choice depends on the specifics of the acquired DCE-MRI data. Additionally, spatial regularization has demonstrated its importance in enhancing the accuracy and reproducibility of results for both models.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Magnetic Resonance in Medicine
ISSN
0740-3194
e-ISSN
1522-2594
Svazek periodika
93
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
13
Strana od-do
2610-2622
Kód UT WoS článku
001423256400001
EID výsledku v databázi Scopus
2-s2.0-85219742503