Comparison of Pulse Wave Arrival Times Measured by Bioimpedance Method and Doppler Ultrasound
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F25%3A00647412" target="_blank" >RIV/68081731:_____/25:00647412 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/25:A2603COY RIV/00159816:_____/25:00082581
Výsledek na webu
<a href="https://www.biomed.cas.cz/physiolres/pdf/2025/74_S155.pdf" target="_blank" >https://www.biomed.cas.cz/physiolres/pdf/2025/74_S155.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.935759" target="_blank" >10.33549/physiolres.935759</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Pulse Wave Arrival Times Measured by Bioimpedance Method and Doppler Ultrasound
Popis výsledku v původním jazyce
Pulse wave velocity is a key indicator of vascular health. This obtained by non-invasive bioimpedance with Doppler ultrasound, the gold standard, at multiple arterial sites. Simultaneous PWAT measurements were performed using bioimpedance (-dZMAX) and Doppler ultrasound (t1 the beginning of the blood flow, t2 the peak of the blood flow, t3 the end of blood flow, t1-2 the midpoint of the blood flow/center between t1 and t2) in healthy volunteers. The agreement between R-dZMAX and the Dopplerderived time points was assessed at various locations. The lowest average error (2.46 %) was observed between R-dZMAX and t1-2, the increase at the midpoint of the systolic flow. However, vascular assessment under various conditions.
Název v anglickém jazyce
Comparison of Pulse Wave Arrival Times Measured by Bioimpedance Method and Doppler Ultrasound
Popis výsledku anglicky
Pulse wave velocity is a key indicator of vascular health. This obtained by non-invasive bioimpedance with Doppler ultrasound, the gold standard, at multiple arterial sites. Simultaneous PWAT measurements were performed using bioimpedance (-dZMAX) and Doppler ultrasound (t1 the beginning of the blood flow, t2 the peak of the blood flow, t3 the end of blood flow, t1-2 the midpoint of the blood flow/center between t1 and t2) in healthy volunteers. The agreement between R-dZMAX and the Dopplerderived time points was assessed at various locations. The lowest average error (2.46 %) was observed between R-dZMAX and t1-2, the increase at the midpoint of the systolic flow. However, vascular assessment under various conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/FW01010543" target="_blank" >FW01010543: Integrovaný telemedicínský systém pro včasnou detekci poruch perireferní perfuze, monitoring a personalizovanou aplikaci neinvazivních terapii se specifickým zaměřením na pacienty s chronickými onemocněními</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
1802-9973
Svazek periodika
74
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
"S155"-"S163"
Kód UT WoS článku
001690902000012
EID výsledku v databázi Scopus
2-s2.0-105027087903