Influence of respirometry methods on intraspecific variation in standard metabolic rates in newts
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081766%3A_____%2F12%3A00377422" target="_blank" >RIV/68081766:_____/12:00377422 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.cbpa.2012.05.201" target="_blank" >http://dx.doi.org/10.1016/j.cbpa.2012.05.201</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.cbpa.2012.05.201" target="_blank" >10.1016/j.cbpa.2012.05.201</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of respirometry methods on intraspecific variation in standard metabolic rates in newts
Popis výsledku v původním jazyce
Standard metabolic rate (SMR) is both a highly informative and variable trait. Variation in SMR stems not only from diverse intrinsic and extrinsic factors, but also from the use of diverse methods for metabolic measurements. We measured CO2 production and oxygen consumption rates using two flow-through respirometry modes, continuous and intermittent (stop-flow), to evaluate their potential contribution to SMR variation in Alpine newts, Ichthyosaura alpestris. Both respirometry modes yielded similar andrepeatable CO2 production values. Although oxygen consumption rate was highly repeatable, continuous respirometry produced lower oxygen consumption rate than the intermittent method. During intermittent measurements, the total number of activity bouts was higher than during continuous respirometry trials. Statistical correction for disparate activity levels minimized variation in oxygen consumption between respirometry modes. We conclude that use of either method of flow-through respiro
Název v anglickém jazyce
Influence of respirometry methods on intraspecific variation in standard metabolic rates in newts
Popis výsledku anglicky
Standard metabolic rate (SMR) is both a highly informative and variable trait. Variation in SMR stems not only from diverse intrinsic and extrinsic factors, but also from the use of diverse methods for metabolic measurements. We measured CO2 production and oxygen consumption rates using two flow-through respirometry modes, continuous and intermittent (stop-flow), to evaluate their potential contribution to SMR variation in Alpine newts, Ichthyosaura alpestris. Both respirometry modes yielded similar andrepeatable CO2 production values. Although oxygen consumption rate was highly repeatable, continuous respirometry produced lower oxygen consumption rate than the intermittent method. During intermittent measurements, the total number of activity bouts was higher than during continuous respirometry trials. Statistical correction for disparate activity levels minimized variation in oxygen consumption between respirometry modes. We conclude that use of either method of flow-through respiro
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EG - Zoologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Comparative Biochemistry and Physiology A-Molecular & Integrative Physiology
ISSN
1095-6433
e-ISSN
—
Svazek periodika
163
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
147-151
Kód UT WoS článku
000306634400018
EID výsledku v databázi Scopus
—