Adaptation of the S-5-S Pendulím Seismometer for Measurement of Rotational Ground Motion
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68145535%3A_____%2F12%3A00382667" target="_blank" >RIV/68145535:_____/12:00382667 - isvavai.cz</a>
Výsledek na webu
<a href="http://link.springer.com/article/10.1007%2Fs10950-012-9279-6" target="_blank" >http://link.springer.com/article/10.1007%2Fs10950-012-9279-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10950-012-9279-6" target="_blank" >10.1007/s10950-012-9279-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Adaptation of the S-5-S Pendulím Seismometer for Measurement of Rotational Ground Motion
Popis výsledku v původním jazyce
The Russian electrodynamic seismometer model S-5-S has been adapted for the measurement of rotational ground motion. The mechanical system of the original S-5-S seismometer consists of electrodynamic sensing and damping transducer coils mounted on an asymmetrical double-arm pendulum. This pendulum is suspended on a footing using two pairs of crossed flat springs, which operate as the axis of rotation. The pendulum is stabilised by an additional spring. The S-5-S can be used either as a vertical or as ahorizontal sensor. The adaptation of the S-5-S seismometer described below involves removal of the additional spring and installation of an additional mass on the damping arm. Strain gauge angle sensors are installed on one pair of the crossed flat springs. The main dynamic parameters of the rotational seismometer created in this way, i.e. the natural period and damping, are controlled electronically by feedback currents proportional to the angular displacement and angular velocity, both
Název v anglickém jazyce
Adaptation of the S-5-S Pendulím Seismometer for Measurement of Rotational Ground Motion
Popis výsledku anglicky
The Russian electrodynamic seismometer model S-5-S has been adapted for the measurement of rotational ground motion. The mechanical system of the original S-5-S seismometer consists of electrodynamic sensing and damping transducer coils mounted on an asymmetrical double-arm pendulum. This pendulum is suspended on a footing using two pairs of crossed flat springs, which operate as the axis of rotation. The pendulum is stabilised by an additional spring. The S-5-S can be used either as a vertical or as ahorizontal sensor. The adaptation of the S-5-S seismometer described below involves removal of the additional spring and installation of an additional mass on the damping arm. Strain gauge angle sensors are installed on one pair of the crossed flat springs. The main dynamic parameters of the rotational seismometer created in this way, i.e. the natural period and damping, are controlled electronically by feedback currents proportional to the angular displacement and angular velocity, both
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DC - Seismologie, vulkanologie a struktura Země
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Seismology
ISSN
1383-4649
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
649-656
Kód UT WoS článku
000308328000008
EID výsledku v databázi Scopus
—