Thermal Manifestations and Nanoindentation of Bone Cements for Orthopaedic Surgery
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68145535%3A_____%2F13%3A00422284" target="_blank" >RIV/68145535:_____/13:00422284 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2298/TSCI130901186H" target="_blank" >http://dx.doi.org/10.2298/TSCI130901186H</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2298/TSCI130901186H" target="_blank" >10.2298/TSCI130901186H</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermal Manifestations and Nanoindentation of Bone Cements for Orthopaedic Surgery
Popis výsledku v původním jazyce
Improving of bone cements properties is possible by research of variables influencing exothermal behaviour and mechanical properties. Paper deals with exothermal behaviour experimental evaluation of bone cements used for medical purposes. Specimens were prepared by a conventional manual mixing technique. The work addresses primary risk factor associated with application of bone cement to femoral canal. Different size samples of bone cement has been created with diameter d = 2 512,5 mm fixed in dentacryl. As an experimental material, Palacos R+G high viscosity, radiopaque bone cement containing Gentamicin and Radiopaque bone cement Antibiotic Simplex with Tobramycin, was used. Thermal effect during exothermic polymerisation was measured with period 1 minute. Evaluated factors were mass and thickness of bone cement. Significant influence of bone cement mass on temperature has been found.
Název v anglickém jazyce
Thermal Manifestations and Nanoindentation of Bone Cements for Orthopaedic Surgery
Popis výsledku anglicky
Improving of bone cements properties is possible by research of variables influencing exothermal behaviour and mechanical properties. Paper deals with exothermal behaviour experimental evaluation of bone cements used for medical purposes. Specimens were prepared by a conventional manual mixing technique. The work addresses primary risk factor associated with application of bone cement to femoral canal. Different size samples of bone cement has been created with diameter d = 2 512,5 mm fixed in dentacryl. As an experimental material, Palacos R+G high viscosity, radiopaque bone cement containing Gentamicin and Radiopaque bone cement Antibiotic Simplex with Tobramycin, was used. Thermal effect during exothermic polymerisation was measured with period 1 minute. Evaluated factors were mass and thickness of bone cement. Significant influence of bone cement mass on temperature has been found.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Thermal Science
ISSN
0354-9836
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CS - Srbsko a Černá Hora
Počet stran výsledku
8
Strana od-do
251-258
Kód UT WoS článku
000338690200027
EID výsledku v databázi Scopus
—