Urinary 8-oxo-7,8-dihydroguanosine values determined by a modified ELISA improves agreement with HPLC-MS/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378041%3A_____%2F13%3A00398237" target="_blank" >RIV/68378041:_____/13:00398237 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.bbrc.2013.09.133" target="_blank" >http://dx.doi.org/10.1016/j.bbrc.2013.09.133</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bbrc.2013.09.133" target="_blank" >10.1016/j.bbrc.2013.09.133</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Urinary 8-oxo-7,8-dihydroguanosine values determined by a modified ELISA improves agreement with HPLC-MS/MS
Popis výsledku v původním jazyce
ELISA is widely used for urinary 8-oxo-7.8-dihydro-2´-deoxyguanosine (8-oxodG) analysis. However, a lack of agreement between ELISA and chromatographic methods confines its application to the assessment of relative urinary 8-oxodG level. We investigatedvarious ELISA modifications, seeking optimal conditions that would yield a good agreement between ELISA and HPLC-MS/MS. It was found, that purification of urine by solid phase extraction, then incubation with the anti-8-oxodG antibody at 40 C overnight and subsequent normalization of 8-oxodG levels per urinary creatinine resulted in a near-perfect correlation and agreement in mean levels between ELISA and HPLC-MS/MS. Our data show that, after introduction of a simple modification, ELISA quantification urinary 8-oxodG substantially improves. This method represents a significant advance for the ELISA, and encouraging its use in more studies adding to our knowledge of the role of this biomarker of oxidative stress in health and disease.
Název v anglickém jazyce
Urinary 8-oxo-7,8-dihydroguanosine values determined by a modified ELISA improves agreement with HPLC-MS/MS
Popis výsledku anglicky
ELISA is widely used for urinary 8-oxo-7.8-dihydro-2´-deoxyguanosine (8-oxodG) analysis. However, a lack of agreement between ELISA and chromatographic methods confines its application to the assessment of relative urinary 8-oxodG level. We investigatedvarious ELISA modifications, seeking optimal conditions that would yield a good agreement between ELISA and HPLC-MS/MS. It was found, that purification of urine by solid phase extraction, then incubation with the anti-8-oxodG antibody at 40 C overnight and subsequent normalization of 8-oxodG levels per urinary creatinine resulted in a near-perfect correlation and agreement in mean levels between ELISA and HPLC-MS/MS. Our data show that, after introduction of a simple modification, ELISA quantification urinary 8-oxodG substantially improves. This method represents a significant advance for the ELISA, and encouraging its use in more studies adding to our knowledge of the role of this biomarker of oxidative stress in health and disease.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DN - Vliv životního prostředí na zdraví
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biochemical and Biophysical Research Communications
ISSN
0006-291X
e-ISSN
—
Svazek periodika
440
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
725-730
Kód UT WoS článku
000326905800045