Performances of an upgraded front-end-board for the NectarCAM camera
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A90247%2F24%3A00643331" target="_blank" >RIV/68378271:90247/24:00643331 - isvavai.cz</a>
Výsledek na webu
<a href="https://pos.sissa.it/444/860/pdf" target="_blank" >https://pos.sissa.it/444/860/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22323/1.444.0860" target="_blank" >10.22323/1.444.0860</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Performances of an upgraded front-end-board for the NectarCAM camera
Popis výsledku v původním jazyce
The Front-End Board (FEB) is a key component of the NectarCAM camera, which has been developed for the Medium-Sized-Telescopes (MST) of the Cherenkov Telescope Array Observatory (CTAO). The FEB is responsible for reading and converting the signals from the camera's photo-multiplier tubes (PMTs) into digital data, as well as generating module level trigger signals. This contribution provides an overview of the design and performances of a new version of the FEB that utilizes an improved version of the NECTAr chip. The NECTAr chip includes a switched capacitor array for sampling signals at 1 GHz, and a 12-bit analog-to-digital converter (ADC) for digitizing each sample when the trigger signal is received. The integration of this advanced NECTAr chip significantly reduces the deadtime of NectarCAM by an order of magnitude as compared to the previous version. This contribution also presents the results of laboratory testing of the new FEB, including measurements of timing performance, linearity, dynamic range, and deadtime.
Název v anglickém jazyce
Performances of an upgraded front-end-board for the NectarCAM camera
Popis výsledku anglicky
The Front-End Board (FEB) is a key component of the NectarCAM camera, which has been developed for the Medium-Sized-Telescopes (MST) of the Cherenkov Telescope Array Observatory (CTAO). The FEB is responsible for reading and converting the signals from the camera's photo-multiplier tubes (PMTs) into digital data, as well as generating module level trigger signals. This contribution provides an overview of the design and performances of a new version of the FEB that utilizes an improved version of the NECTAr chip. The NECTAr chip includes a switched capacitor array for sampling signals at 1 GHz, and a 12-bit analog-to-digital converter (ADC) for digitizing each sample when the trigger signal is received. The integration of this advanced NECTAr chip significantly reduces the deadtime of NectarCAM by an order of magnitude as compared to the previous version. This contribution also presents the results of laboratory testing of the new FEB, including measurements of timing performance, linearity, dynamic range, and deadtime.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Science
ISBN
—
ISSN
1824-8039
e-ISSN
—
Počet stran výsledku
7
Strana od-do
860
Název nakladatele
Sissa Medilab srl
Místo vydání
Trieste
Místo konání akce
Nagoya
Datum konání akce
26. 7. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—