Popis výsledku v původním jazyce
n this work, we report on the possibility of using laser-generated craters to investigate planetary events such as meteorite impact craters. Experiments using a 0.44 mu m/350 ps wavelength laser beam on aluminum foil targets are performed. We obtain simple and complex craters similar in contour to those formed due to meteorite impacts on the terrestrial surface. Our preliminary results show that the central peak of complex craters seems to be higher because of the turbulence beneath the crater floor. Results obtained using a two-dimensional radiation hydrodynamic code, MULTI, show that the laser ablation surface modifies and rises. This could be one of several factors explaining the central peak existence.
Název v anglickém jazyce
Analogy of meteorite impacts in laboratory conditions
Popis výsledku anglicky
n this work, we report on the possibility of using laser-generated craters to investigate planetary events such as meteorite impact craters. Experiments using a 0.44 mu m/350 ps wavelength laser beam on aluminum foil targets are performed. We obtain simple and complex craters similar in contour to those formed due to meteorite impacts on the terrestrial surface. Our preliminary results show that the central peak of complex craters seems to be higher because of the turbulence beneath the crater floor. Results obtained using a two-dimensional radiation hydrodynamic code, MULTI, show that the laser ablation surface modifies and rises. This could be one of several factors explaining the central peak existence.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC528" target="_blank" >LC528: Centrum laserového plazmatu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physica Scripta
ISSN
0031-8949
e-ISSN
—
Svazek periodika
T142
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SE - Švédské království
Počet stran výsledku
5
Strana od-do
"014027/1"-"014027/5"
Kód UT WoS článku
000285777700029
EID výsledku v databázi Scopus
—