Nondestructive Magnetic Adaptive Testing of nuclear reactor pressure vessel steel degradation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F12%3A00387734" target="_blank" >RIV/68378271:_____/12:00387734 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jnucmat.2012.09.006" target="_blank" >http://dx.doi.org/10.1016/j.jnucmat.2012.09.006</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jnucmat.2012.09.006" target="_blank" >10.1016/j.jnucmat.2012.09.006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nondestructive Magnetic Adaptive Testing of nuclear reactor pressure vessel steel degradation
Popis výsledku v původním jazyce
In this work, applicability of a novel magnetic nondestructive method (Magnetic Adaptive Testing, MAT), based on systematic measurement and evaluation of minor magnetic hysteresis loops, is shown for inspection of neutron irradiation embrittlement in nuclear reactor pressure vessel steel. Three series of samples, made of JRQ, 15CH2MFA and 10ChMFT type steels were measured by MAT. The samples were irradiated by E>1 MeV energy neutrons with total neutron fluence of 1.58*1019 ?11.9*1019 n/cm2. Regular correlation was found between the optimally chosen MAT degradation functions and the neutron fluence in all three types of the materials.
Název v anglickém jazyce
Nondestructive Magnetic Adaptive Testing of nuclear reactor pressure vessel steel degradation
Popis výsledku anglicky
In this work, applicability of a novel magnetic nondestructive method (Magnetic Adaptive Testing, MAT), based on systematic measurement and evaluation of minor magnetic hysteresis loops, is shown for inspection of neutron irradiation embrittlement in nuclear reactor pressure vessel steel. Three series of samples, made of JRQ, 15CH2MFA and 10ChMFT type steels were measured by MAT. The samples were irradiated by E>1 MeV energy neutrons with total neutron fluence of 1.58*1019 ?11.9*1019 n/cm2. Regular correlation was found between the optimally chosen MAT degradation functions and the neutron fluence in all three types of the materials.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F09%2F1323" target="_blank" >GA101/09/1323: Nedestruktivní měření stavu oduhličení povrchu ocelí pomocí magnetických metod</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Nuclear Materials
ISSN
0022-3115
e-ISSN
—
Svazek periodika
432
Číslo periodika v rámci svazku
1-3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
371-377