A proof-of-principle experiment of a novel harmonics separation optics for synchrotron facilities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F12%3A00390237" target="_blank" >RIV/68378271:_____/12:00390237 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14740/12:00062763
Výsledek na webu
<a href="http://dx.doi.org/10.1107/S0909049512036618" target="_blank" >http://dx.doi.org/10.1107/S0909049512036618</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1107/S0909049512036618" target="_blank" >10.1107/S0909049512036618</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A proof-of-principle experiment of a novel harmonics separation optics for synchrotron facilities
Popis výsledku v původním jazyce
An experimental proof of a novel higher harmonic separation optics is presented. The higher harmonic separator is a Si crystal cut in an inclined geometry. Due to the inclined geometry, the impinging beam undergoes a diffractive-refractive effect. Due tothe dispersive nature of X-ray refraction a beam containing higher harmonics is after the separator spatially broken down into single diffraction spots. Each spot corresponding to the fundamental energy and its multiples. An X-ray image is presented, where a 7 keV energy beam is spatially separated into a 7 keV diffraction spot and a 21 keV third harmonic diraction spot by 0.35 mm.
Název v anglickém jazyce
A proof-of-principle experiment of a novel harmonics separation optics for synchrotron facilities
Popis výsledku anglicky
An experimental proof of a novel higher harmonic separation optics is presented. The higher harmonic separator is a Si crystal cut in an inclined geometry. Due to the inclined geometry, the impinging beam undergoes a diffractive-refractive effect. Due tothe dispersive nature of X-ray refraction a beam containing higher harmonics is after the separator spatially broken down into single diffraction spots. Each spot corresponding to the fundamental energy and its multiples. An X-ray image is presented, where a 7 keV energy beam is spatially separated into a 7 keV diffraction spot and a 21 keV third harmonic diraction spot by 0.35 mm.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Synchrotron Radiation
ISSN
0909-0495
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DK - Dánské království
Počet stran výsledku
3
Strana od-do
1012-1014
Kód UT WoS článku
000310151000023
EID výsledku v databázi Scopus
—