Popis výsledku v původním jazyce
The Ring Imaging Cherenkov detector (RICH) of the COMPASS experiment at CERN is key tool for particle identification.Two reflecting spherical mirror surfaces, covering a total area of about 21 m2, hosted in the radiator vessel,provide Cherenkov radiationfocusing to photon detectors.These ones are based on the use of multi-anode photo-multiplier tubes.They are coupled to individual lens telescopes, made from special fused silica aspherical lenses. Design, construction, and Hartmann test of lenses qualities and alignment were described. The RICH detector uses C4F10 as radiator gas. The refractive index of the radiator gas is substantial parameter.It varies with temperature, atmospheric pressure and gas purity.Its accurate knowledge is essential for theparticle identification performance.A modified Jamin?s interferometer was proposed,constructed and tested to allow on-line refractive index measurement with accuracy better than 10-6.The new types of fused silica Cherenkov radiators was
Název v anglickém jazyce
New optics for resolution improving of Ring Imaging Cherenkov detectors
Popis výsledku anglicky
The Ring Imaging Cherenkov detector (RICH) of the COMPASS experiment at CERN is key tool for particle identification.Two reflecting spherical mirror surfaces, covering a total area of about 21 m2, hosted in the radiator vessel,provide Cherenkov radiationfocusing to photon detectors.These ones are based on the use of multi-anode photo-multiplier tubes.They are coupled to individual lens telescopes, made from special fused silica aspherical lenses. Design, construction, and Hartmann test of lenses qualities and alignment were described. The RICH detector uses C4F10 as radiator gas. The refractive index of the radiator gas is substantial parameter.It varies with temperature, atmospheric pressure and gas purity.Its accurate knowledge is essential for theparticle identification performance.A modified Jamin?s interferometer was proposed,constructed and tested to allow on-line refractive index measurement with accuracy better than 10-6.The new types of fused silica Cherenkov radiators was
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences: International Conference on Optics and Measurement, OAM 2012
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
00024-00024
Název nakladatele
EDP Sciences
Místo vydání
Cedex
Místo konání akce
Liberec
Datum konání akce
16. 10. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000326985500023