Simple measurement of picosecond laser pulses in a wavelength range above 1?m
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F13%3A00441747" target="_blank" >RIV/68378271:_____/13:00441747 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1117/12.2017524" target="_blank" >http://dx.doi.org/10.1117/12.2017524</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2017524" target="_blank" >10.1117/12.2017524</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simple measurement of picosecond laser pulses in a wavelength range above 1?m
Popis výsledku v původním jazyce
Several simple single-beam non-interferometric measuring techniques for ultrashort laser pulse analysis have been proposed lately (e.g. MIIPS, dispersoscopy). They are based on a compensation of the pulse spectral phase by an acousto-optic pulse shaper followed by a SHG crystal, for example. The output signal is detected by a nonlinear optical medium. Dispersoscopy was originally verified by broadband pulses of Ti:sapphire oscillator and has never been tested in different spectral range or on narrow band subpicosecond pulses. We modified such a dispersoscope for measurement of sub picosecond pulses of an Yb:YAG renerative amplifier generating at wavelength of 1030nm. We also modified the device for measurement of picosecond pulses having their mid-IR wavelength in the range between 2 and 3 microns.
Název v anglickém jazyce
Simple measurement of picosecond laser pulses in a wavelength range above 1?m
Popis výsledku anglicky
Several simple single-beam non-interferometric measuring techniques for ultrashort laser pulse analysis have been proposed lately (e.g. MIIPS, dispersoscopy). They are based on a compensation of the pulse spectral phase by an acousto-optic pulse shaper followed by a SHG crystal, for example. The output signal is detected by a nonlinear optical medium. Dispersoscopy was originally verified by broadband pulses of Ti:sapphire oscillator and has never been tested in different spectral range or on narrow band subpicosecond pulses. We modified such a dispersoscope for measurement of sub picosecond pulses of an Yb:YAG renerative amplifier generating at wavelength of 1030nm. We also modified the device for measurement of picosecond pulses having their mid-IR wavelength in the range between 2 and 3 microns.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
High-Power, High-Energy, and High-Intensity Laser Technology; and Research Using Extreme Light: Entering New Frontiers with Petawatt-Class Lasers
ISBN
978-0-8194-9582-2
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Praha
Datum konání akce
15. 4. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000323516900019