Scintillation properties of Gd3Al2Ga3O12:Ce3+ single crystal scintillators
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F14%3A00432502" target="_blank" >RIV/68378271:_____/14:00432502 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/14:00224046
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2014.03.011" target="_blank" >http://dx.doi.org/10.1016/j.nima.2014.03.011</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2014.03.011" target="_blank" >10.1016/j.nima.2014.03.011</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Scintillation properties of Gd3Al2Ga3O12:Ce3+ single crystal scintillators
Popis výsledku v původním jazyce
The scintillation properties of Gd3Al2Ga3O12:Ce3+ (GAGG:Ce) single crystals grown by the Czochralski method with 1 at% cerium in the melt were investigated and results were compared with so far published results in the literature. The light yield (LY) and energy resolution were measured using a XP5200B photomultiplier. Despite about twice higher LY for GAGG:Ce, the energy resolution is only slightly better than that of LuAG:Ce due to its worse intrinsic resolution and non-proportionality of LY. The LY dependences on the sample thickness and amplifier shaping time were measured. The estimated photofraction in pulse height spectra of 320 and 662 keV ?-rays and the total mass attenuation coefficient at 662 keV ?-rays were also determined and compared withthe theoretical ones calculated using the WinXCom program.
Název v anglickém jazyce
Scintillation properties of Gd3Al2Ga3O12:Ce3+ single crystal scintillators
Popis výsledku anglicky
The scintillation properties of Gd3Al2Ga3O12:Ce3+ (GAGG:Ce) single crystals grown by the Czochralski method with 1 at% cerium in the melt were investigated and results were compared with so far published results in the literature. The light yield (LY) and energy resolution were measured using a XP5200B photomultiplier. Despite about twice higher LY for GAGG:Ce, the energy resolution is only slightly better than that of LuAG:Ce due to its worse intrinsic resolution and non-proportionality of LY. The LY dependences on the sample thickness and amplifier shaping time were measured. The estimated photofraction in pulse height spectra of 320 and 662 keV ?-rays and the total mass attenuation coefficient at 662 keV ?-rays were also determined and compared withthe theoretical ones calculated using the WinXCom program.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP204%2F12%2F0805" target="_blank" >GAP204/12/0805: Pokročilá materiálová řešení pro tenkovrstvé scintilátory a transformátory světla</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
75
Číslo periodika v rámci svazku
Jul
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
1-5
Kód UT WoS článku
000335135500001
EID výsledku v databázi Scopus
—