Novel nanocrystalline diamond coating of coronary stents reduces neointimal hyperplasia in pig model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F14%3A00440840" target="_blank" >RIV/68378271:_____/14:00440840 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/14:43908387 RIV/00216275:25310/14:39897920 RIV/00023001:_____/14:00059149
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Novel nanocrystalline diamond coating of coronary stents reduces neointimal hyperplasia in pig model
Popis výsledku v původním jazyce
Objectives: This study sought to study the performance of nanocrystalline diamond (NCD) coated stainless steel (SS) coronary stent in a pig coronary artery model. Background: Diamond is hard, biocompatible material which offers the possibility of functionalization by covalent carbon chemistry. Results: All animals survived and all stents were patent at 6 weeks. There was a significantly larger lumen area in the NCD group (4.80.97 versus 3.850.87 mm2, p=0.02). The neointimal hyperplasia area was smallerin the NCD group by 37% (1.570.63 mm2 in NCD group versus 2.390.87 mm2 in SS group, p=0.02). There was no difference in stent strut apposition and coverage between NCD and SS group.
Název v anglickém jazyce
Novel nanocrystalline diamond coating of coronary stents reduces neointimal hyperplasia in pig model
Popis výsledku anglicky
Objectives: This study sought to study the performance of nanocrystalline diamond (NCD) coated stainless steel (SS) coronary stent in a pig coronary artery model. Background: Diamond is hard, biocompatible material which offers the possibility of functionalization by covalent carbon chemistry. Results: All animals survived and all stents were patent at 6 weeks. There was a significantly larger lumen area in the NCD group (4.80.97 versus 3.850.87 mm2, p=0.02). The neointimal hyperplasia area was smallerin the NCD group by 37% (1.570.63 mm2 in NCD group versus 2.390.87 mm2 in SS group, p=0.02). There was no difference in stent strut apposition and coverage between NCD and SS group.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KAN200100801" target="_blank" >KAN200100801: Bioaktivní biokompatibilní povrchy a nové nanostrukturované kompozity pro aplikace v medicíně a farmacii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Experimental and Clinical Cardiology
ISSN
1205-6626
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CA - Kanada
Počet stran výsledku
12
Strana od-do
65-76
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—