Bolometric detection of ferromagnetic resonance in amorphous microwires
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F15%3A00448910" target="_blank" >RIV/68378271:_____/15:00448910 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/TMAG.2014.2357074" target="_blank" >http://dx.doi.org/10.1109/TMAG.2014.2357074</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TMAG.2014.2357074" target="_blank" >10.1109/TMAG.2014.2357074</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bolometric detection of ferromagnetic resonance in amorphous microwires
Popis výsledku v původním jazyce
Ferromagnetic resonance (FMR) of glass-coated amorphous Fe78Ni8P10B10 and Co67Fe4Cr7Si8B14 microwires was investigated at frequency 9.54 GHz by the standard FMR and the electrically detected FMR techniques. Static magnetic field was applied parallel to the wire axis and the resonance was driven by the microwave current passing through the wire. The field dependences of electrical resistance measured at different levels of microwave power were compared with the resonance curves obtained by the standard FMR method. It was found that the change of resistance observed at the resonance is caused by the increase of temperature due to the energy dissipation by the Gilbert damping of spin-precession motion.
Název v anglickém jazyce
Bolometric detection of ferromagnetic resonance in amorphous microwires
Popis výsledku anglicky
Ferromagnetic resonance (FMR) of glass-coated amorphous Fe78Ni8P10B10 and Co67Fe4Cr7Si8B14 microwires was investigated at frequency 9.54 GHz by the standard FMR and the electrically detected FMR techniques. Static magnetic field was applied parallel to the wire axis and the resonance was driven by the microwave current passing through the wire. The field dependences of electrical resistance measured at different levels of microwave power were compared with the resonance curves obtained by the standard FMR method. It was found that the change of resistance observed at the resonance is caused by the increase of temperature due to the energy dissipation by the Gilbert damping of spin-precession motion.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F12%2F2177" target="_blank" >GAP102/12/2177: Nanostrukturované magneticky měkké materiály pro sensory</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Transactions on Magnetics
ISSN
0018-9464
e-ISSN
—
Svazek periodika
51
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000349446800055
EID výsledku v databázi Scopus
2-s2.0-84922795788