Monitoring tensile fatigue of superelastic NiTi Wire in liquids by electrochemical potential
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F15%3A00449564" target="_blank" >RIV/68378271:_____/15:00449564 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s40830-015-0020-5" target="_blank" >http://dx.doi.org/10.1007/s40830-015-0020-5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s40830-015-0020-5" target="_blank" >10.1007/s40830-015-0020-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monitoring tensile fatigue of superelastic NiTi Wire in liquids by electrochemical potential
Popis výsledku v původním jazyce
Fatigue of superelastic NiTi wires was investigated by cyclic tension in simulated biofluid. The state of the surface of the fatigued NiTi wire was monitored by following the evolution of the electrochemical open circuit potential (OCP) together with macroscopic stresses and strains. The ceramic TiO2 oxide layer on the NiTi wire surface cannot withstand the large transformation strain and fractures in the first cycle. Based on the analysis of the results of in situ OCP experiments and SEM observation ofcracks, it is claimed that the cycled wire surface develops mechanochemical reactions at the NiTi/liquid interface leading to cumulative generation of hydrogen, uptake of the hydrogen by the NiTi matrix, local loss of the matrix strength, crack transferinto the NiTi matrix, accelerated crack growth, and ultimately to the brittle fracture of the wire.
Název v anglickém jazyce
Monitoring tensile fatigue of superelastic NiTi Wire in liquids by electrochemical potential
Popis výsledku anglicky
Fatigue of superelastic NiTi wires was investigated by cyclic tension in simulated biofluid. The state of the surface of the fatigued NiTi wire was monitored by following the evolution of the electrochemical open circuit potential (OCP) together with macroscopic stresses and strains. The ceramic TiO2 oxide layer on the NiTi wire surface cannot withstand the large transformation strain and fractures in the first cycle. Based on the analysis of the results of in situ OCP experiments and SEM observation ofcracks, it is claimed that the cycled wire surface develops mechanochemical reactions at the NiTi/liquid interface leading to cumulative generation of hydrogen, uptake of the hydrogen by the NiTi matrix, local loss of the matrix strength, crack transferinto the NiTi matrix, accelerated crack growth, and ultimately to the brittle fracture of the wire.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Shape Memory and Superelasticity
ISSN
2199-384X
e-ISSN
—
Svazek periodika
1
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
27
Strana od-do
204-230