Ni-Ti self-expanding vascular stent configuration and biomedical interaction with artery: Finite element analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F17%3A00477150" target="_blank" >RIV/68378271:_____/17:00477150 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/17:PU122586
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/SSP.258.366" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/SSP.258.366</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/SSP.258.366" target="_blank" >10.4028/www.scientific.net/SSP.258.366</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ni-Ti self-expanding vascular stent configuration and biomedical interaction with artery: Finite element analysis
Popis výsledku v původním jazyce
In spite of the fact that the US Food and Drug Administration (FDA) has approved Intracoil and s.m.a.r.t Nitinol stents for superficial femoral artery (SFA), some alternative designs of Nitinol stents are being implanted today, representing the off-label use of the devices. Among the currently stents used for the SFA, s.m.a.r.t and Intracoil stents show the most desirable long-term results but it is not understood why. In the present work, delivery of the s.m.a.r.t and Intracoil Nitinol stents and their release inside a stenotic point of the artery was simulated by FE implemented SMA model using a creative manual controlled method.
Název v anglickém jazyce
Ni-Ti self-expanding vascular stent configuration and biomedical interaction with artery: Finite element analysis
Popis výsledku anglicky
In spite of the fact that the US Food and Drug Administration (FDA) has approved Intracoil and s.m.a.r.t Nitinol stents for superficial femoral artery (SFA), some alternative designs of Nitinol stents are being implanted today, representing the off-label use of the devices. Among the currently stents used for the SFA, s.m.a.r.t and Intracoil stents show the most desirable long-term results but it is not understood why. In the present work, delivery of the s.m.a.r.t and Intracoil Nitinol stents and their release inside a stenotic point of the artery was simulated by FE implemented SMA model using a creative manual controlled method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Solid State Phenomena
ISBN
9783038356264
ISSN
1662-9779
e-ISSN
—
Počet stran výsledku
4
Strana od-do
"258 P (2017)"
Název nakladatele
Trans Tech Publications Ltd.
Místo vydání
Zürich
Místo konání akce
Brno
Datum konání akce
27. 7. 2016
Typ akce podle státní příslušnosti
EUR - Evropská akce