Cryogenic Yb:YGAG ceramic laser pumped at 940 nm and zero-phonon-line: a comparative study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F17%3A00480896" target="_blank" >RIV/68378271:_____/17:00480896 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1364/OME.7.000477" target="_blank" >http://dx.doi.org/10.1364/OME.7.000477</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/OME.7.000477" target="_blank" >10.1364/OME.7.000477</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cryogenic Yb:YGAG ceramic laser pumped at 940 nm and zero-phonon-line: a comparative study
Popis výsledku v původním jazyce
We present a comparative study on a continuous-wave laser operation of Yb-doped Y3Ga2Al3O12 (Yb:YGAG) ceramic at cryogenic temperatures with conventional pumping (940 nm) and zero phonon line pumping (969 nm) under identical experimental conditions. In CW laser operation, at 80 K with ZPL pumping, a maximum output power of 6.53 W with a slope efficiency of 52.0% is achieved with respect to incident power. When compared between two pump sources at cryogenic temperatures, ZPL pumping performs better due to the difference of quantum defect between the two pump sources that results in different heat load in the sample. In passive Q-switching experiment, at 100 K, with 85% initial transmission of Cr:YAG, an average output power of 3.37 W with a repetition rate of 17.6 kHz was achieved.n
Název v anglickém jazyce
Cryogenic Yb:YGAG ceramic laser pumped at 940 nm and zero-phonon-line: a comparative study
Popis výsledku anglicky
We present a comparative study on a continuous-wave laser operation of Yb-doped Y3Ga2Al3O12 (Yb:YGAG) ceramic at cryogenic temperatures with conventional pumping (940 nm) and zero phonon line pumping (969 nm) under identical experimental conditions. In CW laser operation, at 80 K with ZPL pumping, a maximum output power of 6.53 W with a slope efficiency of 52.0% is achieved with respect to incident power. When compared between two pump sources at cryogenic temperatures, ZPL pumping performs better due to the difference of quantum defect between the two pump sources that results in different heat load in the sample. In passive Q-switching experiment, at 100 K, with 85% initial transmission of Cr:YAG, an average output power of 3.37 W with a repetition rate of 17.6 kHz was achieved.n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Optical Materials Express
ISSN
2159-3930
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
477-483
Kód UT WoS článku
000394173200020
EID výsledku v databázi Scopus
2-s2.0-85011866726