Procedures for the relative calibration of the SiPM gain on ASTRI SST-2M camera
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F17%3A00550877" target="_blank" >RIV/68378271:_____/17:00550877 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/content/pdf/10.1007/s10686-016-9516-z.pdf" target="_blank" >https://link.springer.com/content/pdf/10.1007/s10686-016-9516-z.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10686-016-9516-z" target="_blank" >10.1007/s10686-016-9516-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Procedures for the relative calibration of the SiPM gain on ASTRI SST-2M camera
Popis výsledku v původním jazyce
ASTRI SST-2M is one of the prototypes of the small size class of telescopes proposed for the Cherenkov Telescope Array. Its optical design is based on a dual-mirror Schwarzschild-Couder configuration, and the camera is composed by a matrix of monolithic multipixel silicon photomultipliers managed by ad-hoc tailored front-end electronics. This paper describes the procedures for the gain calibration on the ASTRI SST-2M. Since the SiPM gain depends on the operative voltage and the temperature, we adjust the operative voltages for all sensors to have equal gains at a reference temperature. We then correct gain variations caused by temperature changes by adjusting the operating voltage of each sensor.
Název v anglickém jazyce
Procedures for the relative calibration of the SiPM gain on ASTRI SST-2M camera
Popis výsledku anglicky
ASTRI SST-2M is one of the prototypes of the small size class of telescopes proposed for the Cherenkov Telescope Array. Its optical design is based on a dual-mirror Schwarzschild-Couder configuration, and the camera is composed by a matrix of monolithic multipixel silicon photomultipliers managed by ad-hoc tailored front-end electronics. This paper describes the procedures for the gain calibration on the ASTRI SST-2M. Since the SiPM gain depends on the operative voltage and the temperature, we adjust the operative voltages for all sensors to have equal gains at a reference temperature. We then correct gain variations caused by temperature changes by adjusting the operating voltage of each sensor.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Experimental Astronomy
ISSN
0922-6435
e-ISSN
1572-9508
Svazek periodika
43
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
17
Strana od-do
1-17
Kód UT WoS článku
000394212400001
EID výsledku v databázi Scopus
2-s2.0-85007256455