Construction and response of a highly granular scintillator-based electromagnetic calorimeter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F18%3A00501570" target="_blank" >RIV/68378271:_____/18:00501570 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2018.01.016" target="_blank" >http://dx.doi.org/10.1016/j.nima.2018.01.016</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2018.01.016" target="_blank" >10.1016/j.nima.2018.01.016</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Construction and response of a highly granular scintillator-based electromagnetic calorimeter
Popis výsledku v původním jazyce
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5X0 depth and 180 × 180mm2 transverse dimensions was constructed, consisting of 2160 individually read out 10 ×45 × 3mm3 scintillator strips. This prototype was tested using electrons of 2 – 32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be (12.5 ± 0.1(stat.) ± 0.4(syst.))%/pE[GeV] ⊕ (1.2 ± 0.1(stat.)+0.6 −0.7(syst.))%, where the uncertainties correspond to statistical and systematic sources, respectively.n
Název v anglickém jazyce
Construction and response of a highly granular scintillator-based electromagnetic calorimeter
Popis výsledku anglicky
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5X0 depth and 180 × 180mm2 transverse dimensions was constructed, consisting of 2160 individually read out 10 ×45 × 3mm3 scintillator strips. This prototype was tested using electrons of 2 – 32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be (12.5 ± 0.1(stat.) ± 0.4(syst.))%/pE[GeV] ⊕ (1.2 ± 0.1(stat.)+0.6 −0.7(syst.))%, where the uncertainties correspond to statistical and systematic sources, respectively.n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
887
Číslo periodika v rámci svazku
Apr
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
19
Strana od-do
150-168
Kód UT WoS článku
000427814400022
EID výsledku v databázi Scopus
2-s2.0-85041462993