Robust method for long-term energy and pointing stabilization of high energy, high average power solid state lasers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F18%3A00501871" target="_blank" >RIV/68378271:_____/18:00501871 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/18:00327856
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.5018713" target="_blank" >http://dx.doi.org/10.1063/1.5018713</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5018713" target="_blank" >10.1063/1.5018713</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Robust method for long-term energy and pointing stabilization of high energy, high average power solid state lasers
Popis výsledku v původním jazyce
A robust and simple method is presented for ensuring constant energy and pointing of a high average power solid state laser on a target. In addition to providing long-term stability, this scheme also eliminates any drifts in energy or pointing resulting from the initial warm-up after a cold start. This is achieved using two separate feedback loops: one loop stabilizes the pointing of the beam external to the amplifier cavity and the other locks the cavity mode to have optimum overlap with the pump spot on the active medium. The key idea of the cavity mode stabilization is to monitor the overlap of the cavity mode and the gain medium with a camera and control it with an actively controlled, intra-cavity mirror. While this method is demonstrated on a thin-disk regenerative amplifier, it can also be applied to a wide variety of solid state laser amplifiers.
Název v anglickém jazyce
Robust method for long-term energy and pointing stabilization of high energy, high average power solid state lasers
Popis výsledku anglicky
A robust and simple method is presented for ensuring constant energy and pointing of a high average power solid state laser on a target. In addition to providing long-term stability, this scheme also eliminates any drifts in energy or pointing resulting from the initial warm-up after a cold start. This is achieved using two separate feedback loops: one loop stabilizes the pointing of the beam external to the amplifier cavity and the other locks the cavity mode to have optimum overlap with the pump spot on the active medium. The key idea of the cavity mode stabilization is to monitor the overlap of the cavity mode and the gain medium with a camera and control it with an actively controlled, intra-cavity mirror. While this method is demonstrated on a thin-disk regenerative amplifier, it can also be applied to a wide variety of solid state laser amplifiers.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Svazek periodika
89
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000426583500013
EID výsledku v databázi Scopus
2-s2.0-85042226951