The applicability of three different magnetic methods, Magnetic flux leakage technique (MFL), Magnetic adaptive testing and Metal memory method (MMM) was tested for detection of an artificial slot in a system of three steel plates. It was found that MAT resulted in the best signal/noise ratio, and it is capable to detect the bottom side slot even in the three layer configuration. MFL also resulted in acceptable signal/noise ratio in the two layer configuration, but it was not able to detect the slot through two other plates. MMM was not found to be suitable for unstressed and un-magnetized slot detection in the given experimental arrangement.
Název v anglickém jazyce
Inspection of local wall thinning by different magnetic methods
Popis výsledku anglicky
The applicability of three different magnetic methods, Magnetic flux leakage technique (MFL), Magnetic adaptive testing and Metal memory method (MMM) was tested for detection of an artificial slot in a system of three steel plates. It was found that MAT resulted in the best signal/noise ratio, and it is capable to detect the bottom side slot even in the three layer configuration. MFL also resulted in acceptable signal/noise ratio in the two layer configuration, but it was not able to detect the slot through two other plates. MMM was not found to be suitable for unstressed and un-magnetized slot detection in the given experimental arrangement.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
<a href="/cs/project/GB14-36566G" target="_blank" >GB14-36566G: Multidisciplinární výzkumné centrum moderních materiálů</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Nondestructive Evaluation
ISSN
0195-9298
e-ISSN
—
Svazek periodika
37
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
1-8
Kód UT WoS článku
000442050200001
EID výsledku v databázi Scopus
2-s2.0-85052237709