Modelling uncertainty of the radiation energy emitted by extensive air showers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F18%3A00550830" target="_blank" >RIV/68378271:_____/18:00550830 - isvavai.cz</a>
Výsledek na webu
<a href="https://pos.sissa.it/301/303/pdf" target="_blank" >https://pos.sissa.it/301/303/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22323/1.301.0303" target="_blank" >10.22323/1.301.0303</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modelling uncertainty of the radiation energy emitted by extensive air showers
Popis výsledku v původním jazyce
Recently, the energy determination of extensive air showers using radio emission has been shown to be both precise and accurate. In particular, radio detection offers the opportunity for an independent measurement of the absolute energy of cosmic rays, since the radiation energy (the energy radiated in the form of radio signals) can be redicted using first-principle calculations involving no free parameters, and the measurement of radio waves is not subject to any significant absorption or scattering in the atmosphere. Here, we verify the implementation of radiation energy calculations from microscopic simulation codes by comparing Monte Carlo simulations made with the two codes CoREAS and ZHAireS.n
Název v anglickém jazyce
Modelling uncertainty of the radiation energy emitted by extensive air showers
Popis výsledku anglicky
Recently, the energy determination of extensive air showers using radio emission has been shown to be both precise and accurate. In particular, radio detection offers the opportunity for an independent measurement of the absolute energy of cosmic rays, since the radiation energy (the energy radiated in the form of radio signals) can be redicted using first-principle calculations involving no free parameters, and the measurement of radio waves is not subject to any significant absorption or scattering in the atmosphere. Here, we verify the implementation of radiation energy calculations from microscopic simulation codes by comparing Monte Carlo simulations made with the two codes CoREAS and ZHAireS.n
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Science
ISBN
—
ISSN
1824-8039
e-ISSN
—
Počet stran výsledku
8
Strana od-do
1-8
Název nakladatele
Sissa Medilab srl
Místo vydání
Trieste
Místo konání akce
Busan
Datum konání akce
10. 7. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—