Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F19%3A00520479" target="_blank" >RIV/68378271:_____/19:00520479 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/19:00335930 RIV/68407700:21340/19:00335930 RIV/68407700:21670/19:00335930 RIV/00216208:11320/19:10407651 RIV/61989592:15310/19:73596867
Výsledek na webu
<a href="http://hdl.handle.net/11104/0305149" target="_blank" >http://hdl.handle.net/11104/0305149</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/14/09/P09011" target="_blank" >10.1088/1748-0221/14/09/P09011</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
Popis výsledku v původním jazyce
The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas facility. The algorithm output consists of a pair of correction constants per chamber which are applied to baseline calibrations, and determined to be valid for the entire ATLAS Run 2.
Název v anglickém jazyce
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
Popis výsledku anglicky
The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas facility. The algorithm output consists of a pair of correction constants per chamber which are applied to baseline calibrations, and determined to be valid for the entire ATLAS Run 2.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
36
Strana od-do
1-36
Kód UT WoS článku
000486990000011
EID výsledku v databázi Scopus
2-s2.0-85075046132