Design of a high energy Thomson Parabola ion spectrometer for the ELIMAIA beamline
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F19%3A00521638" target="_blank" >RIV/68378271:_____/19:00521638 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1748-0221/14/06/t06004" target="_blank" >https://doi.org/10.1088/1748-0221/14/06/t06004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/14/06/T06004" target="_blank" >10.1088/1748-0221/14/06/T06004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design of a high energy Thomson Parabola ion spectrometer for the ELIMAIA beamline
Popis výsledku v původním jazyce
The ELIMAIA beamline has been installed in the experimental hall dedicated to ion acceleration at ELI-Beamlines. In this paper we propose a design of a first upgrade of the beamline which will allow the use of the already installed energy selection system as a Thomson Parabola spectrometer, which is a key diagnostics for laser-accelerated ion beams. Such ion spectrometer will allow to detect protons up to 300 MeV protons and carbons ions up to 75 MeV per nucleon. Nominal performances of this spectrometer are discussed and compared with calibration of the first magnet of the chicane. Moreover, the main issues in its realization are highlighted and solutions are proposed.
Název v anglickém jazyce
Design of a high energy Thomson Parabola ion spectrometer for the ELIMAIA beamline
Popis výsledku anglicky
The ELIMAIA beamline has been installed in the experimental hall dedicated to ion acceleration at ELI-Beamlines. In this paper we propose a design of a first upgrade of the beamline which will allow the use of the already installed energy selection system as a Thomson Parabola spectrometer, which is a key diagnostics for laser-accelerated ion beams. Such ion spectrometer will allow to detect protons up to 300 MeV protons and carbons ions up to 75 MeV per nucleon. Nominal performances of this spectrometer are discussed and compared with calibration of the first magnet of the chicane. Moreover, the main issues in its realization are highlighted and solutions are proposed.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
22
Strana od-do
1-22
Kód UT WoS článku
000472135900001
EID výsledku v databázi Scopus
2-s2.0-85069559533