Measurement of the charge collection in irradiated miniature sensors for the upgrade of the ATLAS phase-II strip tracker
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F19%3A00540295" target="_blank" >RIV/68378271:_____/19:00540295 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11320/19:10398062
Výsledek na webu
<a href="https://doi.org/10.1016/j.nima.2018.10.007" target="_blank" >https://doi.org/10.1016/j.nima.2018.10.007</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2018.10.007" target="_blank" >10.1016/j.nima.2018.10.007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of the charge collection in irradiated miniature sensors for the upgrade of the ATLAS phase-II strip tracker
Popis výsledku v původním jazyce
Miniature sensors with external dimensions of 10 mm x 10 mm were produced together with full-size sensors for the innermost ring (R0) of the end-cap part in the upgraded ATLAS inner tracker (ITk). AC- and DC-coupled n-type strips with three different pitches (wide, default and narrow) were processed on high-resistivity p-type FZ silicon substrates by Hamamatsu Photonics. The miniature sensors were irradiated with 70-MeV protons at CYRIC, Tohoku University (Japan) and reactor neutrons at the Jožef Stefan Institute (Slovenia) to three different 1-MeV neutron equivalent fluences: 0.5, 1 and 2 x 10 15 neq cm −2 . The upper fluence range exceeds the highest anticipated in the innermost part of the ATLAS ITk-Strips over the HL-LHC lifetime ( ∼ 1.25 × 10 15 n eq cm 2 ). The charge collection in the test sensors was evaluated systematically using a 90 Sr β -source and an Alibava analogue readout system at reverse-bias voltages up to 1000 V.n
Název v anglickém jazyce
Measurement of the charge collection in irradiated miniature sensors for the upgrade of the ATLAS phase-II strip tracker
Popis výsledku anglicky
Miniature sensors with external dimensions of 10 mm x 10 mm were produced together with full-size sensors for the innermost ring (R0) of the end-cap part in the upgraded ATLAS inner tracker (ITk). AC- and DC-coupled n-type strips with three different pitches (wide, default and narrow) were processed on high-resistivity p-type FZ silicon substrates by Hamamatsu Photonics. The miniature sensors were irradiated with 70-MeV protons at CYRIC, Tohoku University (Japan) and reactor neutrons at the Jožef Stefan Institute (Slovenia) to three different 1-MeV neutron equivalent fluences: 0.5, 1 and 2 x 10 15 neq cm −2 . The upper fluence range exceeds the highest anticipated in the innermost part of the ATLAS ITk-Strips over the HL-LHC lifetime ( ∼ 1.25 × 10 15 n eq cm 2 ). The charge collection in the test sensors was evaluated systematically using a 90 Sr β -source and an Alibava analogue readout system at reverse-bias voltages up to 1000 V.n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
924
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
153-159
Kód UT WoS článku
000461827900032
EID výsledku v databázi Scopus
2-s2.0-85055730243